DVP15MC11T Operation Manual
_8
8.7.2
CTD
FB/FC
Explanation
Applicable
model
FB
CTD is used as a down counter.
DVP15MC11T
Parameters
Parameter
name
Meaning
Input/
Output
Description
Valid range
CD
Down-counter
input signal
Input
Control the counter to start counting down TRUE or FALSE
Load
Load signal
Input
For writing the down-counter value
TRUE or FALSE
PV
Preset value
Input
Counter setting value
0 ~ 4294967295
Q
Output signal
Output
Q is TRUE when the counter counts down
to 0.
TRUE or FALSE
CV
Counter value
Output
Counter present value
0 ~ 4294967295
B
ool
ean
Bit string
Integer
Real
number
Time, date
St
rin
g
B
O
O
L
BYT
E
WO
RD
D
WO
R
D
L
W
O
R
D
U
SI
N
T
U
IN
T
U
DI
NT
U
L
INT
SI
N
T
IN
T
D
IN
T
L
IN
T
R
EAL
L
R
EAL
T
IM
E
D
AT
E
TOD
D
T
ST
R
IN
G
CU
●
Load
●
PV
●
Q
●
CV
●
Note:
The symbol
●
indicates that the parameter is allowed to connect to the variable or constant of the data type.
Function Explanation
CTU functions as a down counter.
When
Load
is reset to FALSE after being set to TRUE, the value of
PV
is written to
CV
. When
CD
changes from FALSE to TRUE, the counter makes the counter value decreased once and the value
of
CV
is decreased by 1. When the value of
CV
reaches 0,
Q
is TRUE.
Precautions for Correct Use
While Load is TRUE, the counter will not count down.
CTD
EN
E NO
Q
CTD_ins ta nce
CD
Load
CV
PV
8-48
Summary of Contents for DVP15MC11T
Page 9: ...Memo viii...
Page 15: ...DVP15MC11T Operation Manual _2 MEMO 2 4...
Page 71: ...DVP15MC11T Operation Manual _7 Memo 7 10...
Page 81: ...DVP15MC11T Operation Manual _8 Timing Chart F_TRG_CLK F_TRG_Q 8 10...
Page 158: ...Chapter 8 Logic Instructions 8_ The program 1 ASIN EN ENO In Out ASIN_EN ASIN_In Out1 8 87...
Page 249: ...DVP15MC11T Operation Manual _8 8 178...
Page 285: ...DVP15MC11T Operation Manual _8 Memo 8 214...
Page 323: ...DVP15MC11T Operation Manual 10 MEMO 10 34...
Page 549: ...DVP15MC11T Operation Manual A MEMO A 16...