Basic Inspection 

Item 

Content 

General Inspection 

„

  Periodically inspect the screws of the connection between the HMI and 

device. Tighten screws as necessary as they may loosen due to vibration 
and varying temperatures. 

„

  Ensure that oil, water, metallic particles or any foreign objects do not fall 

inside the HMI, control panel or ventilation slots and holes. As these will 
cause damage. 

„

  Ensure the correct installation and the control panel. It should be free from 

airborne dust, harmful gases or liquids. 

Inspection before 

operation (power is 

not applied) 

„

  Ensure that all wiring terminals are correctly insulated. 

„

  Ensure that all wiring is correct or damage and or malfunction may result. 

„

  Visually check to ensure that there are not any unused screws, metal strips, 

any conductive or inflammable materials inside HMI. 

„

  Ensure to lower electromagnetic interference when devices are influenced 

by it. 

„

  Ensure that the external applied voltage to HMI is correct and matched to the 

controller. 

Inspection before 

operation (power is 

applied) 

„

  Check if power LED lights. 

„

  Check if the communication among devices is normal. 

„

  Please contact your local Delta sales representative if there are any 

abnormal conditions. 

 

Pin Definition of Serial Communication 

COM1 Port (Supports Flow Control) 

Contact 

COM Port   

PIN 

RS-232 

1  

RXD 

3 TXD 

 

5 GND 

 

7 RTS 

CTS 

 
 

 

 

9  

Note: Blank = No Connection. 

COM2 Port (Supports Flow Control) 

MODE1 

MODE2 

MODE3 

COM Port   

PIN 

RS-232 

RS-422 

RS-485 

1   TXD+ D+ 

RXD 

 

 

3 TXD 

 

 

 

RXD+ 

 

5 GND  GND  GND 

 

TXD- 

D- 

7 RTS 

 

 

CTS 

 

 

 
 
 

 

9  RXD-  

  PIN1

 

  PIN1

 

Summary of Contents for B07S200

Page 1: ......

Page 2: ...r distributors or download the most updated version at http www delta com tw industrialautomation Safety Precautions Carefully note and observe the following safety precautions when receiving inspecti...

Page 3: ...uality Installation and Storage Conditions The product should be kept in the shipping carton before installation In order to retain the warranty coverage the HMI should be stored properly when it is n...

Page 4: ...an torque 0 7N M to avoid damage to plastic box Torque 6 17lb inch 0 7N M Step 4 Keep at least 60mm distance from rear of HMI product to the wall installation surface or the other controllers for heat...

Page 5: ...d or malfunction may result Visually check to ensure that there are not any unused screws metal strips any conductive or inflammable materials inside HMI Ensure to lower electromagnetic interference w...

Page 6: ...rackets are the signals used for flow control COM3 Port MODE1 MODE2 MODE3 COM Port PIN RS 232 RS 422 RS 485 1 TXD RTS D 2 RXD 3 TXD 4 RXD CTS 5 GND GND GND 6 TXD RTS D 7 8 9 RXD CTS Note1 Blank No Con...

Page 7: ...nks in red when one of the alarms is on D Operating Display Area NOTE The users can determine the purpose of the operation LED indicator what the operation LED indicator represents in the system menu...

Page 8: ...Type Wide Screen TFT LCD 65536 colors Resolution 480 x 234 pixels Back Light CCFL Back Light about 50 thousand hours at 25o C LCD MODULE Display Size 7 inches wide screen 154 08 x 86 58 mm SDRAM 16M...

Page 9: ...t depends on the temperature used and the conditions of usage about 3 years or more at 25 o C Operation Temp 0 C 50 C Storage Temp 20 C 60 C Ambient Humidity 10 90 RH 0 40 C 10 55 RH 41 50 C Pollution...

Page 10: ...1 DOP B http www delta com tw industrialautomation class 3 100 10...

Page 11: ...2 20 C to 60 C 4 F to 140 F 10 90 Type 4X...

Page 12: ...3 0 7N M 6 17lb inch 0 7N M 60mm AWG 28 12 7 8 mm 5 Kg cm 30 12 7 8 mm 5 Kg cm DOP B07S200 mm...

Page 13: ...2 RS 422 RS 485 1 TXD D 2 RXD 3 TXD 4 RXD 5 GND GND GND 6 TXD D 7 RTS 8 CTS 9 RXD 1 2 COM2 RS 232 RTS CTS COM3 3 COM2 RS 422 COM3 MODE2 COM3 MODE1 MODE2 MODE3 COM Port RS 232 RS 422 RS 485 1 TXD RTS D...

Page 14: ...5 DOP B07S200 A F1 F2 F3 F4 Y Z SYS B C COM USB D C B A D...

Page 15: ...USB Client B COM3 RS232 RS422 RS485 F USB Host C COM2 RS232 RS422 RS485 G D COM1 RS232 215 0 161 0 T 40 5 196 9 1 0 142 9 1 0 4 R3 8 46 6 34 7 75 0 04 5 63 0 04 NOTE T 1 6 mm 0 063 6 mm 0 24 F D C B A...

Page 16: ...CCFL Back Light 25 o C 5 LCD MODULE 7 154 08 x 86 58mm 16Mbytes Bytes 256K Multi Tone Frequency 2K 4K Hz 85dB AUX N A N A CF Card N A USB 3 USB Client 1 Client Ver 1 1 USB Host 3 COM1 RS 232 COM2 RS 2...

Page 17: ...H 0 40 C 10 55 RH 41 50 C 2 IEC61131 2 5Hz 9Hz 3 5mm 9Hz 150Hz 1G 5Hz 9Hz 1 75mm 9Hz 150Hz 0 5G X Y Z 10 W x H x D mm 215 x 161 x 50 W x H mm 196 9 x 142 9 800g NOTE 1 DOP B HMI Screen Editor http www...

Page 18: ...1 DOP B http www delta com tw industrialautomation class 3 100 10...

Page 19: ...2 20 C to 60 C 4 F to 140 F 10 90 Type 4X...

Page 20: ...3 0 7N M 6 17lb inch 0 7N M 60mm AWG 28 12 7 8 mm 5 Kg cm 30 12 7 8 mm 5 Kg cm DOP B07S200 mm...

Page 21: ...2 RS 422 RS 485 1 TXD D 2 RXD 3 TXD 4 RXD 5 GND GND GND 6 TXD D 7 RTS 8 CTS 9 RXD 1 2 COM2 RS 232 RTS CTS COM3 3 COM2 RS 422 COM3 MODE2 COM3 MODE1 MODE2 MODE3 COM Port RS 232 RS 422 RS 485 1 TXD RTS D...

Page 22: ...5 DOP B07S200 A F1 F2 F3 F4 Y Z SYS B C COM USB D C B A D...

Page 23: ...USB Client B COM3 RS232 RS422 RS485 F USB Host C COM2 RS232 RS422 RS485 G D COM1 RS232 215 0 161 0 T 40 5 196 9 1 0 142 9 1 0 4 R3 8 46 6 34 7 75 0 04 5 63 0 04 NOTE T 1 6 mm 0 063 6 mm 0 24 F D C B A...

Page 24: ...ixels CCFL Back Light 25 o C 5 LCD MODULE 7 154 08 x 86 58mm 16Mbytes Bytes 256K Multi Tone Frequency 2K 4K Hz 85dB AUX N A N A CF Card N A USB 3 USB Client 1 Client Ver 1 1 USB Host 3 COM1 RS 232 COM...

Page 25: ...0 90 RH 0 40 C 10 55 RH 41 50 C 2 IEC61131 2 5Hz 9Hz 3 5mm 9Hz 150Hz 1G 5Hz 9Hz 1 75mm 9Hz 150Hz 0 5G X Y Z 10 W x H x D mm 215 x 161 x 50 W x H mm 196 9 x 142 9 800g NOTE 1 DOP B HMI Screen Editor ht...

Reviews: