ASDA-B2
Chapter 4 Display and Operation
Revision September 2013
4-9
4.4.2 JOG Operation
After entering parameter mode P4-05, the users can follow the following steps to
perform JOG operation. (Please also refer to Figure 4.4).
Step1.
Press the SET key to display the JOG speed. (The default value is 20 r/min).
Step2.
Press the UP or DOWN arrow keys to increase or decrease the desired JOG
speed. (This also can be undertaken by using the SHIFT key to move the
cursor to the desired unit column (the effected number will blink) then changed
using the UP and DOWN arrow keys. The example display in Figure 4.4 is
adjusted as 100 r/min.)
Step3.
Press the SET key when the desired JOG speed is set. The Servo Drive will
display "JOG".
Step4.
Press the UP or DOWN arrow keys to jog the motor either CCW or CW. The
motor will only rotate while the arrow key is activated.
Step5.
To change JOG speed again, press the MODE key. The servo Drive will
display "P4 - 05". Press the SET key and the JOG speed will displayed again.
Refer back to #2 and #3 to change speed.
NOTE
1) JOG operation is effective only when Servo On (when the servo drive is enabled).
VARITEL INGENIERIA ELECTRONICA S.A.
[email protected] - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.