Chapter 6 Control Modes of Operation
6.1 Control Modes of Operation
The Delta ASDA-B series Servo can be programmed to provide five single and three dual modes of
operation. Their operation and description is listed in the following Table 6.A.
Mode
Code
Description
External Position
Control
P 00
Position control for the servo motor is achieved via an external
pulse command.
Speed Control
S
02
Speed control for the servo motor can be achieved via
parameters set within the controller or from an external analog -
10 ~ +10 Vdc command. Control of the internal speed
parameters is via the Digital Inputs (DI). (A maximum of three
speeds can be stored internally).
Internal Speed
Control
Sz 04
Speed control for the servo motor is only achieved via
parameters set within the controller. Control of the internal
speed parameters is via the Digital Inputs (DI). (A maximum of
three speeds can be stored internally).
Torque Control
T
03
Torque control for the servo motor can be achieved via
parameters set within the controller or from an external analog -
10 ~ +10 Vdc command. Control of the internal torque
parameters is via the Digital Inputs (DI). (A maximum of three
torque levels can be stored internally).
Single
Mode
Internal Torque
Control
Tz 05
Torque control for the servo motor is only achieved via
parameters set within the controller. Control of the internal
torque parameters is via the Digital Inputs (DI). (A maximum of
three torque levels can be stored internally).
S-P 06
Either S or P control mode can be selected via the Digital Inputs
(DI). (Please refer to Chapter 7 for more detailed DI setting.)
T-P 07
Either T or P control mode can be selected via the Digital Inputs
(DI). (Please refer to Chapter 7 for more detailed DI setting.)
Dual Mode
S-T 10
Either S or T control mode can be selected via the Digital Inputs
(DI). (Please refer to Chapter 7 for more detailed DI setting.)
Table 6.A
The steps of changing mode:
(1)
Switching the servo drive to Servo Off status. Turning SON signal of Digit input to be off can complete
this action.
(2)
Using parameter P1-01. (Refer to chapter 7).
(3)
After the setting is completed, cut the power off and restart the drive again.
Summary of Contents for ASD-B0121-A
Page 1: ......
Page 13: ...Table of Contents ASDA B Series Revision January 2009 This page intentionally left blank...
Page 72: ...Chapter 4 Display and Operation ASDA B Series Revision January 2009 4 17 Figure 4 7...
Page 75: ...Chapter 4 Display and Operation ASDA B Series 4 20 Revision January 2009 Figure 4 9...
Page 77: ...Chapter 4 Display and Operation ASDA B Series 4 22 Revision January 2009 Figure 4 10...
Page 79: ...Chapter 4 Display and Operation ASDA B Series 4 24 Revision January 2009 Figure 4 11...
Page 92: ...Chapter 4 Display and Operation ASDA B Series Revision January 2009 4 37 Figure 4 21...
Page 291: ...Chapter 12 Application Examples ASDA B Series 12 2 Revision January 2009 PLC Program...
Page 292: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 3...
Page 293: ...Chapter 12 Application Examples ASDA B Series 12 4 Revision January 2009...
Page 297: ...Chapter 12 Application Examples ASDA B Series 12 8 Revision January 2009 Position Control 1...
Page 298: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 9 Position Control 2...
Page 299: ...Chapter 12 Application Examples ASDA B Series 12 10 Revision January 2009 JOG Operation...
Page 302: ...Chapter 12 Application Examples ASDA B Series Revision January 2009 12 13...