Chapter 7 Servo Parameters
|
ASDA-A&A+ Series
7-20
Revision April 2009
7.3 Detailed Parameter Listings
Group 0: P0-xx Monitor Parameters
P0 - 00
★
VER
Firmware Version
Communication Addr.: 0000H
Default: Factory setting
Related Section: N/A
Applicable Control Mode: ALL
Unit: N/A
Range: N/A
P0 - 01
★
ALE
Drive Fault Code
Communication Addr.: 0001H
Default: Factory setting
Related Section:
Applicable Control Mode: ALL
Chapter 10
Unit: N/A
Range: 00 ~ 23 (ASDA-A series)
00 ~ 25 (ASDA-A+ series)
Settings:
01: Overcurrent
02: Overvoltage
03: Undervoltage
04: Reserved (ASDA-A Series)
"Mismatch" error (ASDA-A+ Series)
05: Regeneration error
06: Overload
07: Overspeed
08: Abnormal pulse control command
09: Excessive deviation
10: Watch dog fault
11: Position detector fault
12: Adjustment error
13: Emergency stop
14: Reverse limit error
15: Forward limit error
16: IGBT temperature error
17: Memory error
18: DSP communication error
19: Serial communication error
20: Serial communication time out
21: DSP to MCU command write-in error
22: Input power phase loss
23: Pre-overload warning
24: Encoder Error (ASDA-A+ Series only)
25: Encoder Error (ASDA-A+ Series only)