background image

EN

16

17

> 3s

> 3s

x 2

x 1

The motor has already been associated with a transmitter.
You can associate various transmitters from the X3D range (telephone transmitter, 
other remote control, etc.) with the up/down function of the motor. Number of 

transmitters that may be associated: 16 max.

To associate these transmitters, please consult their instructions.
An additional user guide describing the operation of the TYMOOV motor with the 

TYXIA 1712 and TYXIA 2330 remote controls is available on the website 

 

www.deltadore.com.

The stops must first be removed then set again for them to be modified.

Remove them by proceeding as follows:

See section 4.2 “setting stops” to set them again.

5/  Modifying stops 

6/  Associating another transmitter

> 3s

x 2

The motor

will be activated briefly.

twice.

Press  button B on the front 
panel of the remote control, 

 until the LED flashes green.

On the transmitter, press and hold 
the 

 et 

 buttons at 

the same time for more than 3 
seconds until the LED comes on.

The stops will now be 

removed

The new

remote control

will now be 

associated with the 

motor

On the transmitter that is already 
associated, press the 

 

button for more than 3 seconds 

until the motor is activated briefly.

Validate on the transmitter to be 
associated  (e.g. new remote control)

On the new remote control,
press the 

 and 

 

buttons at the same time for 
more than 3 seconds  until the 
LED comes on.

The motor will briefly

be activated twice.

You want to control the opening of roller shutters in the event that smoke is 
detected. 

Motor type

Linking to a wireless smoke detector

TYMOOV xRP2 and DxRP2

Wireless smoke detector directly linked to the motor

TYMOOV xRE2  

(Version >  S02.04.00)

Wireless smoke detector directly linked to the motor

TYMOOV xRE2 

 (Version <  S02.04.00)

Only by linking your motor and the wireless smoke detector to a 

TYXAL+ alarm system

To find out the type and version of the motor, consult the «Troubleshooting» 

chapter.

7/  Linking a smoke detector directly to the 
motor

> 3s

x 2

x 1

When the motors have been associated via a bidirectional grouped command, they 

will start up at slightly staggered time intervals (100 ms) in order to limit the peak 

current in the electric line during start-up.
• If the motors were associated at the same time in a grouped command, they will 
start up in the order in which they were detected during the association process. 

E.g. It could be that one lounge motor starts first, followed by a bedroom motor, 
then the second lounge motor. There may be a time lapse between the first and 

second lounge motors starting.

• If you would like the motors to start in a specific order, you should associate them 

one by one in the order you require.
Refer to the user guide for each remote control. 
E.g. If you have 3 roller shutter motors in one lounge, associate them one by one 
with the remote control so that they start up without a big time lapse.

8/  Grouped command

On the transmitter that is already 
associated, press the 

 button for 

more than 3 seconds until the motor is 

activated briefly.

Briefly press the button of the detector.
The motor will briefly be activated 

twice.

Summary of Contents for TYMOOV 10RE2

Page 1: ...EN Wireless Tubular Motor range TYMOOV radio xRP2 DxRP2 xRE2 ...

Page 2: ...nd that the risks involved have been understood Children must not play with the device Cleaning and maintenance by the user must not be carried out by unsupervised children The operating device of an unlockable switch must be in direct view of the driven part but kept away from the moving parts It must be installed at a height of at least 1 5 m The fixed control devices must be installed in a visi...

Page 3: ...type A plate on the motor indicates the nominal torque and operating time TYMOOV xRP2 DxRP2 or xRE2 tubular motors are designed to operate intermittently 4 minutes of continuous operation They are electronically protected to prevent overheating If there is a thermal shutdown the motor will operate again after a time period of approximately 30 seconds To operate again for 4 minutes the motor must h...

Page 4: ...g the first remote control to a motor 11 4 2 Setting stops 12 5 Modifying stops 16 6 Associating another transmitter 16 7 Linking a smoke detector directly to the motor 17 8 Grouped command 17 9 Obstacle detection 18 9 1 Setting of the obstacle detection type 18 9 2 Adjustment of the sensitivity of obstacle detection for Basic detection only 19 10 Remove one or several associations 19 10 1 Remove ...

Page 5: ...ling L Total length TYMOOV 6 10 and 20 Nm 395 mm 424 mm Tube L length for drilling wheel attachment by screws or rivet 2 3 Motor head position The motor head must be positioned on the mount such that the cable outlet is in the lower part when seen horizontally 2 4 Attaching the motor to the mount Push the tube motor A onto the mount B until it locks into place click 8 NO 8 NO 8 NO 4 OK 4 OK 4 OK C...

Page 6: ...associate The corresponding shutter will be activated briefly once Once the motor has been found press briefly After a few seconds the shutter will be activated briefly twice to confirm the association To exit association mode hold for 3 seconds You will then be able to pass to Set stops mode 3s The electrical wiring must comply with EN IEC and national institute standards for installation e g NF ...

Page 7: ...n slightly so that there is no force on the shutter x 1 Upper physical stop Lower physical stop Stop on shutter blade Press the button briefly until the shutter reaches the upper stop The stop position will now be automatically set The motor will be activated briefly The stop position will now be automatically set The motor will be activated twice Automatic upper stop Automatic lower stop The stop...

Page 8: ...lease the and buttons at the same time To scroll step by step briefly press then release the and buttons at the same time Press button B on the front panel of the remote control until the LED flashes green Then press and hold the button for 3 seconds until the motor is activated briefly The upper manual stop will now be set The motor will be activated briefly Press the button to move the shutter t...

Page 9: ...he opening of roller shutters in the event that smoke is detected Motor type Linking to a wireless smoke detector TYMOOV xRP2 and DxRP2 Wireless smoke detector directly linked to the motor TYMOOV xRE2 Version S02 04 00 Wireless smoke detector directly linked to the motor TYMOOV xRE2 Version S02 04 00 Only by linking your motor and the wireless smoke detector to a TYXAL alarm system To find out the...

Page 10: ... DxRP2 motors you have a choice between two detection modes Protect Detection default mode more efficient obstacle detection preventing the apron from unwinding in the casing Basic Detection detection of obstacles with unwinding of the apron in the casing Repeat the operations above to switch between modes The Radio Efficacité xRE2 motor only has Basic obstacle detection 3s x 2 Press button B on t...

Page 11: ...unit to Maintenance mode then to Add product mode Set the alarm control unit to Add product mode Associate the intruder mode with the alarm control unit Press button B on the front panel of the remote control twice until the LED flashes orange Then press and hold the button for 3 seconds until the motor is activated briefly The alarm control unit will beep The alarm control unit will beep The roll...

Page 12: ...t the motor is in association wait mode it only remains in association mode for 2 minutes 12 2 Associating an Efficacité RE2 radio motor 12 3 Defining the motor s operating mode 5s Bip ON OFF 3s x 1 x 2 On the motor remote control press the button for more than 3 seconds until the motor operates briefly Set the alarm control unit to Maintenance mode open it and then briefly press button 2 of the c...

Page 13: ... stop then a manual stop Press the push button 2 seconds so that the motor operates in the up or down direction When the motor detects the 1st stop upper or lower then the motor operates once 2s x 1 OR x 3 2s 2s x 2 2s x 2 STOP OR Press the push button 2 seconds so that the motor operates in the opposite direction Briefly press the push button to stop the motor at the position corresponding to the...

Page 14: ...2 manual stops x 3 2s 2s x 2 2s x 2 STOP OR Press the push button 2 seconds so that the motor operates in the up or down direction Briefly press the push button to stop the motor at the position corresponding to the manual stop Then if the shutter is down briefly press the push button 3 times then press and hold the push button 2 seconds if the shutter is up briefly press the push button 2 times t...

Page 15: ...n on the remote control 3 times The motor operates twice x 2 x 1 TYMOOV xRP2 and DxRP2 software version S02 04 00 and higher The motor operates once x 2 x 1 TYMOOV xRE2 software version S02 04 00 and higher The motor does not respond TYMOOV xRE2 or xRP2 or DxRP2 software version S02 04 00 See label on the motor 17 Troubleshooting Press the push button once to move the shutter down or up Switch off...

Page 16: ...www deltadore com 05 21 ...

Reviews: