About the eZFC-424R4-24
Page 8 of 84
eZFC-424R4-24 Application Guide
Edition 2.6
About the eZFC-424R4-24
The eZFC-424R4-24 and eZFCP-424R4-24 controllers are native BACnet controllers optimized
for fan coil applications. It has multiple input and output configuration options covering a wide range
of fan coil configurations including single or multi-speed fans, 2-pipe or 4-pipe systems, with or
without change-over. The controller is also designed to be compatible with Delta Controls’ eZNS
and DNS-24L network sensors.
The eZFC-424R4-24 comes preloaded with algorithms which you configure using a configuration
graphic to match your site’s needs. There are 2 types of eZFC-424R4-24 controllers: both the
configurable (eZFC) and programmable (eZFCP) models use the configuration graphic for setup
but only the programmable controller allows you to overwrite the default sequences with General
Control Language (GCL) programming.
You can use ORCAview 3.40R3 and higher or enteliWEB 4.1 and higher to access the
configuration graphic.
About This Guide
This application guide introduces the controller and describes the differences between the
configurable and programmable models. The guide also shows you how to use the configuration
graphic in ORCAview 3.40 R3 and higher to set up your eZFC-424R4-24 controller. The product
name eZFC-424R4-24 in this guide refers to both the configurable and programmable models
unless stated otherwise.
The ORCAview configuration graphic version referenced in this guide is B-169041.1.
For help with the eZFC-424R4-24 configuration page in enteliWEB 4.3 and higher, go to the online
help in enteliWEB. enteliWEB users require the applicable object permissions to change the
settings on the configuration page.
The installation guide for the eZFC-424R4-24 can be found on the eZFC-424R4-24
product web page on the Delta Controls Support web site.
Upgrading Firmware
Upgrading From 1.x to 2.2
The configurable algorithm database on firmware version 1.01 is not compatible with the
configurable algorithm database on firmware 2.2. See the release notes of the firmware version
you are upgrading to for more information.
Summary of Contents for eZFC-424R4-24
Page 1: ...eZFC 424R4 24 Application Guide Edition 2 6...
Page 67: ...enteliZONE Sequence of Operations Page 66 of 84 eZFC 424R4 24 Application Guide Edition 2 6...
Page 70: ...eZFC 424R4 24 Application Guide Edition 2 6 Page 69 of 84...
Page 71: ...enteliZONE Sequence of Operations Page 70 of 84 eZFC 424R4 24 Application Guide Edition 2 6...