DelRay MONTIGO DRL3613LI Installation & Maintenance Manual Download Page 44

44

Appendix

XG0226 - 042220

Appendix B: Warranty

MONTIGO RESIDENTIAL WARRANTY PROGRAM

Canadian Heating Products Inc. and/or Montigo DelRay Corp 

(collectively referred to herein as "The Companies"), warrants the 

Montigo gas appliance (referred to herein as 'the appliance') to 

be free from defects in materials and workmanship at the time 

of manufacture. The gas appliance and related components are 

further subject to the terms and conditions set forth below.

This warranty covers the following Montigo product series: 

Distinction, Divine & Divine Outdoor (H-Series), Illume (FID Inserts), 

Phenom (L/P/PL-Series), Exemplar (R/RP-Series), Mahana and DelRay

Component

Coverage Period

Labor Coverage

Firebox, heat exchanger

15 years

1 year

Main burner

15 years

1 year

Gas control valve and related control components 

(pilot assembly, spark electrode flame sensors, 

thermopile)

1 year

1 year

Electrical components (internal blowers, ignition 
control module, wiring, switches, remote control 
systems, blower control module, accent bulbs)

1 year

1 year

Firebox media (logset, glass beads, river rocks)

1 year

1 year

Glass (thermal breakage)

1 year

1 year

Plated, painted finishes (including interior reflective 

glass) *

1 year

1 year

Refractory lining

1 year

1 year

Mesh/Glass safety barriers

1 year

1 year

Power vent termination

1 year

1 year

Montigo terminations*

10 years

1 year

Montigo venting (excluding termination)

15 years

1 year

* Exterior painted surfaces exempt

QUALIFICATIONS TO THE WARRANTY

This Warranty only covers gas appliances installed in the United 

States or Canada.

To receive the benefits of this warranty, the appliance must 

be purchased, installed and serviced annually by a dealer 

authorized by The Companies for the warranty to be valid.

The gas appliance must be installed by a licensed professional 

in accordance with The Companies' installation instructions 

and local building codes. The warranty on the appliance covers 

only components manufactured by The Companies. The use of 

components manufactured or supplied by other manufacturers 

and used in conjunction with the appliance could create serious 

safety hazards, may result in the denial of certification by 

recognized national safety agencies and could violate local 

building codes. Such use may untimely void this warranty. This 

warranty does not cover any damages occurring from the 

use of any components not manufactured or supplied by The 

Companies.

The appliance must be subjected to normal use. The appliance 

is designed to burn natural gas (NG) or liquefied petroleum (LP) 

only. Burning conventional fireplace fuels such as wood, coal or 

any other solid fuel will cause damage to the appliance, produce 

excessive temperatures will result in a fire hazard and void all 

warranties. This warranty is transferable. The appliance must 

remain in its original place of installation to be valid.
If the components of the appliance covered by this warranty 

are found to be defective within the time frame stated (see The 

Companies investigation of claims), The Companies will, at its 

option, replace or repair defective components of the appliance 

manufactured by The Companies at no charge and will also 

pay for labor costs (in accordance with schedule) incurred in 

replacing or repairing components. If repair or replacement 

is not commercially practical, The Companies will, at its sole 

discretion, fully discharge all obligations under the warranty by 

refunding the verified dealer purchase price of the appliance, 

excluding the cost of labor unless the labor is covered by the 

terms of the warranty.

This warranty covers only parts and labor as provided above. 

In no case shall the companies be responsible for materials, 

components or construction, which are not manufactured or 

supplied by The Companies, or for the labor necessary to install, 

repair or remove such materials, components or construction. All 

replacement or repair components will be shipped F.O.B. from 

the nearest Company factory.

LIMITATION ON LIABILITY

It is agreed and understood that The Companies sole obligation, 

and purchaser's exclusive remedy under this warranty, under 

any other warranty, expressed or implied, or in contract, tort or 

otherwise, shall be limited to repair, replacement or refund as 

specified above. The opinion of The Companies with respect to 

these matters shall be final.
In no event shall The Companies be responsible for any 

incidental or consequential damages caused by (but not limited 

to) improper installation, installation by an unqualified or 

unauthorized installer, accident, lack of regular maintenance, 

user error, abuse, misuse, Acts of God, power surges, floods, 

natural disasters, force majeure, defects in its appliance whether 

such damage occurs or is discovered before or after replacement 

or repair, and whether or not such damage is caused by The 

Companies negligence. Some jurisdictions do not allow the 

exclusion or limitation of incidental or consequential damages, 

so the above limitation or exclusion may not apply to you. The 

duration of any implied warranty with respect to the appliance 

is limited to the duration of the foregoing warranty. Some 

jurisdictions do not allow limitations on how long an implied 

warranty lasts, so the above limitation or exclusion may not 

apply to you.

Summary of Contents for MONTIGO DRL3613LI

Page 1: ...2 21 000 BTU NG 19 000 BTU Propane hr DRL6013NI 28 000 BTU NG 25 000 BTU Propane hr DRL6013NI 2 28 000 BTU NG 25 000 BTU Propane hr A barrier designed to reduce the risk of burns from the hot viewing...

Page 2: ...or approved by Montigo in combination with this Montigo fireplace system Installation other than as instructed in this manual Consult your local Gas Inspection Branch on installation requirements for...

Page 3: ...ng when using cool wall kit or vented chase 25 Chase venting optional 26 Sidewall clearances 27 Cement Board Install 27 Section 8 Removing Installing the Screen Door 28 Removing the Screen 28 Reinstal...

Page 4: ...223 1 NFPA 54 Electrical installations must conform to the local codes or in the absence of local codes to the current version of the National Electrical Code ANSI NFPA 70 See Appendix C for installat...

Page 5: ...stalled fastened and secured in place maintaining proper clearance Firestops installed Exteriorwall roofflashinginstalledandsealedincompliancewithlocalbuildingcode Terminations installed and sealed in...

Page 6: ...verre and crans de certifi s avec l appareil seulement Refer to installation manual for more information R f rez vous au manuel d installation pour plus d information Serial No N H 0 4500 ft 0 1371 m...

Page 7: ...263 4 165 8 69 16 1411 16 361 2 4 5 7 Figure 2 DelRay Fireplace dimensions Tolerance DRL 3613 DIMENSIONS A B C D 413 8 383 8 361 2 451 4 DRL 4813 DIMENSIONS A B C D 535 16 505 16 481 2 571 4 DRL 6013...

Page 8: ...1 2 1206 47 1 2 1705 67 1 8 1101 100 43 3 8 Finish DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL 1 32 TWO PLACE DECIMAL 015 THREE PLACE DECIMAL 005 ALL BENDS ARE ASSUMED TO BE 90 UNLESS NOTED OTHERW...

Page 9: ...vinyl flooring can be sensitive to radiant heat and changes in temperature If using vinyl flooring we recommend you install the fireplace in one of the ways shown below The minimum width of the heart...

Page 10: ...size NO RECESS NON COMBUSTIBLE FACING Enclosure top Enclosure top Combustible header Venting ports closed Combustible facing material not allowed with standard minimum chase WARNING Cement board Comb...

Page 11: ...nting ports open back wall must be enclosed no exposed insulation vapor barrier IMPORTANT Leaving the venting ports open requires a minimum chase height of 6 Venting ports shown on a DRL3613 Vented ch...

Page 12: ...acceptable Once the termination location has been established refer to the appropriate section below for installation details All fireplaces shipped from the factory are top vent Silicone application...

Page 13: ...ng flex kit The maximum vent system consists of 34 vertical length with 4 90 bends and a 20 horizontal length measured to center of pipe Maximum Vertical vent run 34 verticallengthwitharooftermination...

Page 14: ...linear installation requires reducing from Montigo 4 7 to Duravent 4x6 Theappliancecanbeadaptedtoco linearapplicationsusinganexisting chimney Theappliancemustnotbeconnectedtoachimneyflueserving asepar...

Page 15: ...181 Class 1 requirements 970 38 3 16 51 2 OPENING 53 2 1 16 1653 65 1 16 OPENING 1678 66 1 16 76 3 38 1 1 2 533 21 236 9 5 16 180 7 1 16 1 24 DWG NO SHEET 3 OF 3 WEIGHT DL63 Heat distribution TV kit...

Page 16: ...e Drawn by DATE NAME 05 05 2017 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CAN...

Page 17: ...FRACTIONAL 1 32 TWO PLACE DECIMAL 015 THREE PLACE DECIMAL 005 ANGULAR 5 ALL BENDS ARE ASSUMED TO BE 90 UNLESS NOTED OTHERWISE Unscrew Cap and replace with supplied Crimp Collars using the same hardwa...

Page 18: ...ACTIONAL 1 32 TWO PLACE DECIMAL 015 THREE PLACE DECIMAL 005 ANGULAR 5 ALL BENDS ARE ASSUMED TO BE 90 UNLESS NOTED OTHERWISE Unscrew Cap and replace with supplied Crimp Collars using the same hardware...

Page 19: ...T OR PROPRIETARY AND CONFIDENTIAL DIMENSIONS ARE IN TOLERANCES FRACTIONAL 1 3 TWO PLACE DECIM THREE PLACE DEC ANGULAR 5 ALL BENDS ARE AS TO BE 90 UNLESS OTHERWISE 1 12 DWG NO WEIGHT Finish MATERIAL Re...

Page 20: ...iled diagram of allowed termination locations see Appendix A Amaximumoftwooffsets eachoffsetismadeupof2 90 bends may be made for vertical vent runs 2 45 bends are equivalent to 1 90 Firestops must be...

Page 21: ...the interior side of the studs concrete or finished wall construction using a minimum of 4 screws 3 Insert the termination into the MOSR frame as shown here from the inside and attach to the MOSR by i...

Page 22: ...en the outer and inner pipes to keep the pipes separate and avoid any possible hot spots Montigo recommends the use of a flex section for the first section of venting connected directly to the firepla...

Page 23: ...46DVA 06 6 Section 46DVA 09 9 Section 46DVA 12 12 Section 46DVA 18 18 Section 46DVA 24 24 Section 46DVA 36 36 Section 46DVA 48 48 Section 46DVA 60 60 Section 4D6 6 4D12 12 4D18 18 4D24 24 4D36 36 4D48...

Page 24: ...lars Reduce horizontal run by 36 for each 90 offset after the first one Support straps OR Support ring and plates Support straping Must convert from flex to rigid before termination Support ring and p...

Page 25: ...he structure To complete the installation fasten the Heat Shield Outer Section Termination frame to the structure Figure 15 e RHS100 Installation Figure 15 c RHS100 Installation Install by sliding Out...

Page 26: ...Local Codes Installations in the USA must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 Optional remote contro...

Page 27: ...ppliedwiththeapplianceisreplaced it must be replaced with the same type or its equivalent Figure 17 Wiring diagram for DRL3613NI 2 with SIT Proflame Electronic Ignition MODEL DRL3613 I 2 DRL4813 I 2 D...

Page 28: ...nect incoming gas line to the 1 2 or 3 8 gas inlet port Check appliance connection valve and valve train under normal operatingpressurewithacommerciallyavailableleakchecksolution DO NOT USE A FLAME OF...

Page 29: ...ing THE OPENINGMUST NOT BE OBSTRUCTED IN ANYWAY todosorestrictstheairsupplyforthecontrolcompartments and heat exchanger it also prevents access for servicing controls CAUTION Combustible Mantle Height...

Page 30: ...cketing at the top of the enclosure A minimum of 2 from the top of a chase vent to the ceiling is needed Any combination of the above examples is an acceptable chase vent providing they add up to the...

Page 31: ...rd Assembly Finish MATERIAL DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL 1 32 TWO PLACE DECIMAL 015 THREE PLACE DECIMAL 005 ANGULAR 5 ALL BENDS ARE ASSUMED TO BE 90 UNLESS NOTED OTHERWISE Revision D...

Page 32: ...he appliance Figure 20 Locate the three tabs at the base of the screen Figure 20 b Lift out the Retaining Tabs and screen NOTICE STEP 1 Remove lower valve blinds and screen setting bar STEP 1 Line up...

Page 33: ...r to loosen off the NG gas orifice replace with Propane orifice as included in package 5 Remove natural gas mixer sleeve from burner Reinstall burner Propane Conversion Tools required 1 Torx T20 Screw...

Page 34: ...ion label on valve face 10 The pilot size can be adjusted using a flathead screwdriver to adjust pilADJ screw shown 9 See regulator instructions for guide on converting the pressure regulator gasket 1...

Page 35: ...e Only cover the burner with one layer of firestones or fireglass Section 9 Installing the Accessories Figure 24 b Completed firestone installation DelRay 36 Optional Log Kit Installation Propane Drif...

Page 36: ...ayout The Fireplace has the option of installing a drift wood log set Once the base media of fireglass firestones or speckled stones has been placed the log set can be installed Ensure logs are secure...

Page 37: ...ayout The Fireplace has the option of installing a drift wood log set Once the base media of fireglass firestones or speckled stones has been placed the log set can be installed Ensure logs are secure...

Page 38: ...anifold Pressure Test Connection Pilot Adjustment Screw Inlet Pressure Test Connection Output Regulator Control Optional A barrier designed to reduce the risk of burns from the hot viewing glass is pr...

Page 39: ...ual deposit of a white substance on combustion chamber walls This can easily be removed using normal household products Use a vacuum cleaner or whisk broom to keep the control compartment burner and f...

Page 40: ...te operating instructions In order to start your pilot turning the main burner on with the switch remote or thermostat and then turning it off will reactivate the continuous pilot mode and reset the s...

Page 41: ...necessary Pilot Igniter sparking but Pilot burner will not light 1 Verify the Inlet and Manifold Gas Pressure are within acceptable limits 2 Check all connections to gas valve 3 Check connection to s...

Page 42: ...g fireplace penetration of an exterior building envelope Dimension A X 75 min overhang depth The overhang must extend at least 75 of the roof line height A Height is measured from bottom of fireplace...

Page 43: ...bustion air inlet to other appliance for appliance 100 000 BTU H 30 KW 12 inches 12 inches M clearance to forced air supply inlet 6 feet 3 feet above air inlet N clearance above paved sidewalk or pave...

Page 44: ...m LP only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the appliance produce excessive temperatures will result in a fire hazard and void all war...

Page 45: ...itten consent of The Companies The Companies shall in no event be responsible for any warranty work done without first obtaining the Companies written consent The Companies employees and dealers have...

Page 46: ...he sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS Appendix C Amendment Gas Fireplace Equipment sold in the State of Massach...

Page 47: ...EN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED PROPRIETARY AND CONFIDENTIAL Y Products Residential Products R D Projects DelRay DelRay Linear MNR36 DRL36 TRIM KIT 1 5in 2in CLEARANCE DRL36 1...

Page 48: ...ear MNR36 DRL36 TRIM KIT 1 5in 2in CLEARANCE DRL36 1 5 2in TRIM FRAME ASSY Wednesday April 08 2020 12 19 54 PM SCALE MTK FIN OPTIONS SHEET 21 20 OPTIONS SHEET 22 23 24 25 PARTS LIST PAGE 1 ITEM PART D...

Page 49: ...C1386 FUSE 3 5A 13 RGC3094 PROFLAME2 BASIC CONTROL BOARD 14 REC3062 REPLACMENT PROFLAME2 BOARD HARNESS OPTIONS 15 DRLT48 0 11 16 ADJUSTABLE TRIM KIT 16 DRLT48 2 1 1 2 2 ADJUSTABLE TRIM KIT 17 RX40 DEL...

Page 50: ...S 19 REC3062 PROFLAME2 BOARD HARNESS 30 RAFBDRL4813 FAN DEFLECTOR OPTIONS 20 DRLT48 0 11 16 ADJUSTABLE TRIM 21 DRLT48 2 1 1 2 2 ADJUSTABLE TRIM 22 REC1493 WALL MOUNT PROFLAME2 REMOTE 23 GCA019 LPG CON...

Page 51: ...3094 PROFLAME2 BASIC CONTROL BOARD 14 REC3062 REPLACMENT PROFLAME2 BOARD HARNESS OPTIONS 15 DRLT48 0 11 16 ADJUSTABLE TRIM KIT 16 DRLT48 2 1 1 2 2 ADJUSTABLE TRIM KIT 17 RX40 DELRAY ON OFF REMOTE 18 R...

Page 52: ...OFLAME2 BOARD HARNESS 30 RAFBDRL4813 FAN DEFLECTOR OPTIONS 20 DRLT48 0 11 16 ADJUSTABLE TRIM 21 DRLT48 2 1 1 2 2 ADJUSTABLE TRIM 22 REC1493 WALL MOUNT PROFLAME2 REMOTE 23 GCA019 LPG CONVERSION KIT 24...

Page 53: ...53 Notes XG0226 042220...

Page 54: ...XG0226 042220 Installation Maintenance Manual DelRay DelRay Single Sided Gas Fireplace Single Sided Gas Fireplace...

Reviews: