Profi
Message
l
from 15 m: 1000 kbaud (standard setting)
l
up to 20 m: 500 kBaud
l
up to 45 m: 333.3 kbaud
l
up to 60 m: 250 kBaud
l
up to 150m: 100 kbaud
The baud rate must be the same for transmission and reception. Therefore,
determine firstly the baud rate for the equipment communicated with and use this
value to set the CAN connection’s baud rate.
The detail in brackets shows for which protocol this baud rate is available (CiA =
CAN in automation, DCP =
Delphin
CAN protocol).
Extended ID
A CAN system identifies data not by device addresses, but by identifiers within a
message. The CAN specification defines identifiers at either 11 or 29 bits in
length. The setting determines which identifier length is used.
When enabled, this option can be used with either an 11-bit or 29-bit (CAN 2.0B)
identifier. When not enabled, data transmission on the CAN bus is limited to an 11-
bit identifier (CAN 2.0A) and no other setting can be made with
4.8.2.1
CAN protocol
Create a channel for the CAN protocol via the context menu
Create channel
→
CAN
protocol (RAW)
of the CAN connection.
The
symbol is then displayed for the CAN protocol.
Double-click the CAN protocol or select Properties from the context menu to display
the configuration dialogue. Use the dialogue to enter a name, location and descrip-
tion for the CAN protocol.
170
Delphin Technology AG
Dezember 2015
Profi
Message Manual
Summary of Contents for ProfiMessage
Page 1: ......
Page 31: ...ProfiMessage 3 5 4 ADIT 31 Delphin Technology AG Dezember 2015 ProfiMessage Manual ...
Page 32: ...ProfiMessage 3 5 5 ADVT 3 5 6 AMDT 32 Delphin Technology AG Dezember 2015 ProfiMessage Manual ...
Page 33: ...ProfiMessage 3 5 7 DIOT 3 5 8 IOIT 33 Delphin Technology AG Dezember 2015 ProfiMessage Manual ...
Page 314: ...ProfiMessage 314 Delphin Technology AG Dezember 2015 ProfiMessage Manual ...
Page 322: ......