5
Auxiliary ignition
Should the piezoelectric starter fail to work, repeat the operation described above, using a
match to light the pilot flame.
Turning off the heater
To turn off the heater, close the gas bottle tap.
The appliance will be completely off only when the gas bottle tap is closed.
Important
When the large knob is released at the end of the ignition time (see the rating plate and
instruction booklet), it must return upwards by around 5 mm to its initial position. If this does
not happen, close the gas tap and contact your after-sales service centre. Never operate the
appliance with the large knob held downwards by force.
Important
DO NOT cover the appliance when in operation, this could cause a dangerous risk of fire.
Important notes
-
Use the appliance only standing on the floor.
- The heater must always operate in upright position.
- Never direct the hater air flow towards furniture, curtains , spray cans and inflammable
material.
- Do not install the appliance in a room which might contain gas, oil or sulphur, or near
sources of heat.
- After an extended period when the heater is not in use check the “O”-Ring Seal before
lighting up the heater. Replace the “O” Ring Seal if cracked or broken.
-
Do not use the appliance in the mountains at high altitudes.
-
DIARISE: During March/April of each year check the “O” Ring Seal.
MAINTENANCE
Wipe your appliance with a soft damp cloth and only when it is switched off, cold and
unplugged. Do not use solvents or abrasives detergents.
Check that there is no dust blocking the air inlet or outlet grids. Clean using a vacuum clea-
ner. When not in use remove plug from socket and store cable. When not in use the heater
should be covered and stored in a dust-free place. Refer any major maintenance to your
Technical Assistance Service. Major servicing should be carried out every 2 - 3 years. If in
doubt refer to your nearest Technical Assistance Service.
GB-5721009200 4-12-2003 12:08 Pagina 5