background image

Do not store or use gasoline or other flammable vapors and liquids
in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your

building.

• lmmediately call your gas supplier from a neighbor's phone.

Follow the gas supplier's instructions.

• lf you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer,
service agency, or the gas supplier.

WARNING:

IF THE INFORMATION IN THIS MANUAL IS NOT

FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT
CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.

IMPORTANT - PLEASE READ AND FOLLOW

Before beginning, please read these instructions completely and carefully.

Do not remove permanently affixed labels, warnings, or plates from the product. This
may void the warranty.

Please observe all local and national codes and ordinances.

Please ensure that this product is properly grounded.

The installer should leave these instructions with the consumer who should retain
for local inspector's use and for future reference.

The electrical plug should always be accessible

Installation must conform with local codes or in the absence of codes, the National Fuel
Gas Code ANSIZ223.1 - Iatest edition. Electrical installation must be in accordance with the
National Electrical Code, ANSI/NFPA70 - latest edition and/or local codes. IN CANADA:
Installation must be in accordance with the current CAN/CGA-B149.1 National Gas
Installation Code or CAN/CGA-B149.2, Propane Installation Code and/or local codes.
Electrical installation must be in accordance with the current CSA C22.1 Canadian
Electrical Codes Part 1 and/or local codes.

Installation of any gas-fired equipment should be made by a Iicensed plumber. A manual
gas shut-off valve must be installed in the gas supply line ahead of the appliance in the gas
stream for safety and ease of service.

B U I L T - I N

G A S

C O O K T O P

with safety valve device

• USERS OPERATING INSTRUCTIONS
• INSTALLATION ADVICE

Model  

DEGCT424F..

Summary of Contents for DEGCT424 Series

Page 1: ...ces Please ensure that this product is properly grounded The installer should leave these instructions with the consumer who should retain for local inspector s use and for future reference The electr...

Page 2: ...this booklet carefully It may be useful in future either to yourself or to others in the event that doubts should arise relating to its operation This appliance must be used only for the task it has...

Page 3: ...The appliance should be installed and all the gas electrical connections made by a qualified engineer in compliance with local regulations in force and following the manufacturer s instructions TIPS...

Page 4: ...c gas lighting device is incorporated into the knobs The appliance has a safety valve system fitted the flow of gas will be stopped if and when the flame should accidentally go out CAUTION If the burn...

Page 5: ...ng adjustments can be achieved by positioning the indicator between the maximum and minimum aperture positions and never between the maximum aperture and OFF positions N B When the cooktop is not bein...

Page 6: ...r with a chamois leather For difficult dirt use a specific non abrasive product available commercially or a little hot vinegar Note regular use could cause discolouring around the burners because of t...

Page 7: ...fig 3 1 next to each burner is always clean to ensure correct operation of the safety valves Both the probe and ignition plug must be very carefully cleaned Both the probe and ignition plug must be v...

Page 8: ...alteration services or maintenance can cause injury or property damage Consult a qualified installer service agent or the gas supplier INSTALLATION INSTRUCTIONS TOOLS NEEDED FOR INSTALLATION Screwdri...

Page 9: ...ance before servicing 9 When removing appliance for cleaning and or service A Shut off gas at main supply B Disconnect AC power supply C Disconnect gas line to the inlet pipe D Carefully lift applianc...

Page 10: ...ig 4 2b 22 53 64 580 mm 19 11 16 500 mm 2 9 16 65 mm 18 7 8 480 mm 2 9 16 65 mm 24 610 mm 22 1 64 560 mm CUT OUT CUT OUT min 4 102 mm from cut out 19 11 16 500 mm 2 5 32 55 mm 2 5 32 55 mm 2 9 16 65 m...

Page 11: ...front of the countertop and also between the back side of the cooktop and the back of the countertop Important Base cabinet construction must allow for size of cooktop cutout Gas line opening Wall an...

Page 12: ...om as the cooktop and should be in a location that allows ease of opening and closing in a position where it can be reached quickly in the event of an emergency Do not block access to the shutoff valv...

Page 13: ...not to damage the thread STEP 2 Mount the extension pipe to the elbow connection interposing the gasket supplied and tighten by using a wrench When tightening keep the elbow connection firm i e by usi...

Page 14: ...cylindrical ISO 228 1 female 3 8 NPT conical male 3 8 NPT female 3 8 NPT female WARNING check the right positioning of the gas regulator The arrow on the back of the gas regulator must be oriented to...

Page 15: ...mount a step down regulator will be required e The appliance its individual shut off valve and pressure regulator must be disconnected from the gas supply piping system during any pressure testing of...

Page 16: ...the cooktop All strains must be removed from the supply and fuel lines so cooktop will be level and in line Use joint compounds and gaskets that are resistant to action of natural or propane gas on a...

Page 17: ...sconnected and then connected again to the gas supply line repeat the operations indicated in paragraph 5 Leak Testing at page 16 OPERATIONS TO BE PERFORMED WHEN SUBSTITUTING THE INJECTORS Remove the...

Page 18: ...und method For your personal safety this cooktop must be grounded This cooktop is equipped with a 3 prong ground plug To minimize possible shock hazard the cord must be plugged into a mating 3 prong g...

Page 19: ...19 Wiring diagram key A Ignition coil PA Ignition switches group M Terminal block CA Igniter Fig 6 2 A N L PA M CA CA CA CA WIRING DIAGRAM...

Page 20: ...anscription errors in the present booklet The manufacturer reserves the right to make all modifications to its products deemed necessary for manufacture or commercial reasons at any moment and without...