background image

See Rating

label

Type

Category

Max.output         Med.output           Low output

Kw

g/h

4.2

305

Kw

g/h

2.85

207

Kw

g/h

1.50

109

28-30 mbar

8.4 m

3

/h

Gas

combustion air 

quantity

this appliance is designed  to operate with butane, at nominal pressure: 28÷30 mbar

GENERAL SAFETY INSTRUCTIONS

CYLINDER VALVE

If heater does not competely extinguish, including pilot, when gas is turned off at the regulator, do not remove regulator. Return valve
to open position and leave heater alight, which is perfectly safe, until attended to by the gas supplier.

Regulators, Hoses and clips

Check that tubing is completely over the nozzles at each end of the tubing and that is held firmly in place by tube clips. Examine
flexible tubing regularly and get your Dealer to fit new tubing 400 mm long if perished, worn or
damaged. L.P.G. ATTACKS NATURAL RUBBER-USE ONLY TUBING TO B.S. 3212 TYPE 2 SUPPLIED
BY YOUR DEALER.
Avoid bending or constricting the rubber tube when the pressure regulator is connected to the gas
cylinder.
A REGULATOR B.S. 3016 SET AT 28 MBAR (11.2 IN W.G.) for butane must de connected to the
appliance with the above tubing, using suitable tube clips.

VENTILATION

USE ONLY IN A WELL VENTILATED ROOM

Adequate ventilation must be provided in rooms in which the heater is use. This ensures removal of the products combustion and
allows the entry of replacement air.
Adequate ventilation should considerably reduce the possibility of condensation accurring.
The following table shows the smallest size of room suitable for each heat setting and the ventilation which must be provided.

MAINTENANCE

Ensure that the heater is kept free of dust. When the heater is not in use it should be covered and stored in a dust-free place. Stains
on the exterior should be removed with soapy solution when the heater is cold. Dry with a polishing cloth. DO NOT use abrasive
cleaners which will damage the paint finishes.
Refer any major maintenance to your Local Authorised Dealer. Major servicing should be carried out annually. If in doubt refer to your
authorised dealer.

SAFETY GUARD

The guard on this appliance conforms to the requirements of B.S. 1945: 1971 and  satisfies the heater appliance (fireguards)
regulations. The guard is to prevent risk of fire or injury from burns and no part of it should be permanently removed. 

It does not give

full protection for young children or the infirm.

105 cm

2

MIN

MAX

MED

Room

Size

Room

Vent

15 m

3

42 m

3

28,5 m

3

Heating Setting

4

Gas 

Presure 

Reviews: