Table 11. System setup options—Passwords menu (continued)
Passwords
Password Configuration
Upper Case Letter
Reinforces password must have at least one upper case letter.
By default, the option is disabled.
Lower Case Letter
Reinforces password must have at least one lower case letter.
By default, the option is disabled.
Digit
Reinforces password must have at least one digit.
By default, the option is disabled.
Special Character
Reinforces password must have at least one special character.
By default, the option is disabled.
Minimum Characters
Set the minimum characters allowed for password.
Password Bypass
When enabled, this always prompts for computer and internal hard drive
passwords when powered on from the off state.
By default, the
Disabled
option is enabled.
Password Changes
Enable Non-Admin Password Changes
Enable or disable to change computer and hard drive password without the
need for admin password.
By default, the option is enabled.
Admin Setup Lockout
Enable Admin Setup Lockout
Enables administrators control over how their users can or cannot access BIOS
setup.
By default, the option is disabled.
Master Password Lockout
Enable Master Password Lockout
When enabled, this will disable the master password support.
By default, the option is disabled.
Allow Non-Admin PSID Revert
Enable Allow Non-Admin PSID Revert
Controls access to the Physical Security ID (PSID) revert of NVMe hard-drives
from the Dell Security Manager prompt.
By default, the option is disabled.
Table 12. System setup options—Update, Recovery menu
Update, Recovery
UEFI Capsule Firmware Updates
Enable or disable BIOS updates through UEFI capsule update packages.
By default, the option is enabled.
BIOS Recovery from Hard Drive
Enables the user to recover from certain corrupted BIOS conditions from a
recovery file on the user primary hard drive or an external USB key.
By default, the option is enabled.
BIOS Downgrade
Allow BIOS Downgrade
Enable or disable the flashing of the computer firmware to previous revision is
blocked.
By default, the option is enabled.
58
System setup
Summary of Contents for Vostro 5890
Page 1: ...Vostro 5890 Service Manual Regulatory Model D28M Regulatory Type D28M004 August 2021 Rev A01 ...
Page 36: ...36 Disassembly and reassembly ...
Page 44: ...44 Disassembly and reassembly ...
Page 45: ...Disassembly and reassembly 45 ...
Page 47: ...Disassembly and reassembly 47 ...
Page 48: ...48 Disassembly and reassembly ...
Page 49: ...Disassembly and reassembly 49 ...