NOTE: For the latest best practices, see the Dell Storage Center Best Practices document on the
Dell TechCenter site (
http://en.community.dell.com/techcenter/storage/
Two Servers Connected to Dual 12 Gb 4-Port SAS Storage Controllers
A storage system with four 12 Gb front-end SAS ports on each storage controller can connect up to two
host servers, if each host server has two SAS HBAs with dual SAS ports.
About this task
This configuration includes four fault domains spread across both storage controllers. The storage
controllers are connected to each host server using four SAS connections.
If a storage controller becomes unavailable, all of the standby paths on the other storage controller
become active.
Steps
1.
Connect fault domain 1 (shown in orange) to host server 1.
a. Connect a SAS cable from storage controller 1: port 1 to the first SAS HBA on host server 1.
b. Connect a SAS cable from storage controller 2: port 1 to the first SAS HBA on host server 1.
2.
Connect fault domain 2 (shown in blue) to host server 1.
a. Connect a SAS cable from storage controller 1: port 2 to the second SAS HBA on host server 1.
b. Connect a SAS cable from storage controller 2: port 2 to the second SAS HBA on host server 1.
3.
Connect fault domain 3 (shown in gray) to host server 2.
a. Connect a SAS cable from storage controller 1: port 3 to the first SAS HBA on host server 2.
b. Connect a SAS cable from storage controller 2: port 3 to the first SAS HBA on host server 2.
4.
Connect fault domain 4 (shown in red) to host server 2.
a. Connect a SAS cable from storage controller 1: port 4 to the second SAS HBA on host server 2
b. Connect a SAS cable from storage controller 2: port 4 to the second SAS HBA on host server 2
Connect the Front-End Cabling