Figure 60. Wrap Label Around Cable
3.
Apply a matching label to the other end of the cable.
Cabling Direct-Attached Host Servers
An SC4020 storage system with front-end SAS ports connects directly to host servers. Each host bus
adapter (HBA) can attach to one SAS fault domain.
NOTE: To configure an SC4020 storage system with front-end SAS ports, see the
Dell SC4020
Storage System Front-End SAS Configuration Tech Note
.
Preparing Host Servers
On each host server, install the SAS host bus adapters (HBAs), install the drivers, and make sure that the
latest supported firmware is installed.
About this task
NOTE: Refer to the
Dell Storage Compatibility Matrix
for a list of supported SAS HBAs.
Steps
1.
Install the SAS HBAs in the host servers.
NOTE: Do not install SAS HBAs from different vendors in the same server.
2.
Install supported drivers for the HBAs and make sure that the HBAs have the latest supported
firmware installed.
3.
Use the SAS cabling diagram to cable the host servers directly to the storage system.
NOTE: If deploying vSphere hosts, configure only one host at a time.
SAS Virtual Port Mode
To provide redundancy in SAS virtual port mode, the front-end ports on each storage controller must be
directly connected to the server.
In SAS virtual port mode, a volume is active on only one storage controller, but it is visible to both storage
controllers. Asymmetric Logical Unit Access (ALUA) controls the path that a server uses to access a
volume.
Connect the Front-End Cabling