![Dell SC4020 Deployment Manual Download Page 171](http://html.mh-extra.com/html/dell/sc4020/sc4020_deployment-manual_79827171.webp)
B
HBA Server Settings
This appendix provides recommended HBA card settings that provide the most effective communication
between the server and the Storage Center.
Settings by HBA Manufacturer
Storage Center has been tested to work with servers using Dell, Emulex, and Qlogic HBA cards.
NOTE: Emulex and Qlogic HBA cards require additional configuration to improve the connection
speeds between the server and the Storage Center. For more information regarding the
compatibility of an HBA card, see the
Dell Storage Compatibility Matrix
Dell 12Gb SAS Cards
Dell 12Gb SAS cards are fully compatible with Storage Center and do not require further configuration.
For more information, see the Dell Storage best practices.
Cisco Fibre Channel Cards
Cisco manufactures HBA cards that are compatible with Dell Storage Center. Configure Cisco fibre
channel cards with the following settings:
Field
Setting
FCP Error Recovery
Disabled (default)
Flogi Retries
60
Flogi Timeout
4000 (default)
Plogi Retries
60
Plogi Timeout
20000 (default)
Port Down Timeout
10000 (default)
Port Down IO Retry
60 (default)
Link Down Timeout
30000 (default)
NOTE: For more information regarding the compatibility of an HBA card, see the
Emulex HBA Cards
Emulex manufactures HBA cards for iSCSI and Fibre Channel connections that are compatible with Dell
Storage Centers.
NOTE: For more information regarding the compatibility of an HBA card, see the
HBA Server Settings