Display the Link Trace Cache.
EXEC Privilege mode
show ethernet cfm traceroute-cache
•
Delete all Link Trace Cache entries.
EXEC Privilege mode
clear ethernet cfm traceroute-cache
Example of Viewing the Link Trace Cache
Dell#show ethernet cfm traceroute-cache
Traceroute to 00:01:e8:52:4a:f8 on Domain Customer2, Level 7, MA name Test2 with VLAN 2
------------------------------------------------------------------------------
Hops Host IngressMAC Ingr Action Relay Action
Next Host Egress MAC Egress Action FWD Status
------------------------------------------------------------------------------
4 00:00:00:01:e8:53:4a:f8 00:01:e8:52:4a:f8 IngOK RlyHit
00:00:00:01:e8:52:4a:f8 Terminal MEP
Enabling CFM SNMP Traps
An SNMP trap is sent only when one of the five highest priority defects occur.
Table 8. Five Highest Priority Defects
Priority Defects
Trap Message
Cross-connect defect
%ECFM-5-ECFM_XCON_ALARM: Cross connect fault
detected by MEP 1 in Domain customer1 at
Level 7 VLAN 1000
Error-CCM defect
%ECFM-5-ECFM_ERROR_ALARM: Error CCM Defect
detected by MEP 1 in Domain customer1 at
Level 7 VLAN 1000
MAC Status defect
%ECFM-5-ECFM_MAC_STATUS_ALARM: MAC Status
Defect detected by MEP 1 in Domain provider
at Level 4 VLAN 3000
Remote CCM defect
%ECFM-5-ECFM_REMOTE_ALARM: Remote CCM Defect
detected by MEP 3 in Domain customer1 at
Level 7 VLAN 1000
RDI defect
%ECFM-5-ECFM_RDI_ALARM: RDI Defect detected
by MEP 3 in Domain customer1 at Level 7 VLAN
1000
Three values are given within the trap messages: MD Index, MA Index, and MPID. You can reference these values against the output
of the
show ethernet cfm domain
and
show ethernet cfm maintenance-points local mep
commands
To enable CFM SNMP traps, use the following command.
•
Enable SNMP trap messages for Ethernet CFM.
CONFIGURATION mode
snmp-server enable traps ecfm
Example of Viewing CFM SNMP Trap Information
Dell#show ethernet cfm maintenance-points local mep
--------------------------------------------------------------------
MPID Domain Name Level Type Port CCM-Status
90
802.1ag
Summary of Contents for S4048-ON
Page 1: ...Dell Configuration Guide for the S4048 ON System 9 9 0 0 ...
Page 146: ...Figure 14 BFD Three Way Handshake State Changes 146 Bidirectional Forwarding Detection BFD ...
Page 522: ...Figure 87 Configuring Interfaces for MSDP 522 Multicast Source Discovery Protocol MSDP ...
Page 523: ...Figure 88 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 523 ...
Page 528: ...Figure 91 MSDP Default Peer Scenario 1 528 Multicast Source Discovery Protocol MSDP ...
Page 529: ...Figure 92 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 529 ...
Page 530: ...Figure 93 MSDP Default Peer Scenario 3 530 Multicast Source Discovery Protocol MSDP ...
Page 633: ...Policy based Routing PBR 633 ...
Page 777: ...Figure 119 Single and Double Tag TPID Match Service Provider Bridging 777 ...
Page 778: ...Figure 120 Single and Double Tag First byte TPID Match 778 Service Provider Bridging ...