background image

- 5 - 

 

 

1.2 SAFETY: General Power Safety 

Observe the following guidelines when connecting your equipment to a power source: 
 

 

Check the voltage rating before you connect the equipment to an electrical outlet to ensure 
that the required voltage and frequency match the available power source. 

 

Do not plug the equipment power cables into an electrical outlet if the power cable is 
damaged 

 

Norway and Sweden: If this product is provided with a 3-prong power cable, connect the 
power cable to a grounded electrical outlet only. 

 

If you use an extension power cable, ensure that the total ampere rating of the products 
plugged in to the extension power cable does not exceed the ampere rating of the extension 
cable. 

 

If you must use an extension cable or power strip, ensure the extension cable or power strip 
is connected to a wall power outlet and not to another extension cable or power strip. The 
extension cable or power strip must be designed for grounded plugs and plugged into a 
grounded wall outlet. 

 

If you are using a multiple-outlet power strip, use caution when plugging the power cable into 
the power strip. Some power strips may allow you to insert a plug incorrectly. Incorrect 
insertion of the power plug could result in permanent damage to your equipment, as well as 
risk of electric shock and/or fire. Ensure that the ground prong of the power plug is inserted 
into the mating ground contact of the power strip. 

 

Be sure to grasp the plug, not the cable, when disconnecting equipment from an electric 
socket. 

 

If your equipment uses an AC adapter: 
 

 

Use only the Dell provided AC adapter approved for use with this device. Use of another AC 
adapter may cause a fire or explosion. 

 

NOTE: Refer to your system rating label for information on the proper adapter model 
approved for use with your device. 

 

Place the AC adapter in a ventilated area, such as a desk top or on the floor, when you use 
it to run the computer or to charge the battery. Do not cover the AC adapter with papers or 
other items that will reduce cooling; also, do not use the AC adapter inside a carrying case. 

 

The AC adapter may become hot during normal operation of your computer. Use care when 
handling the adapter during or immediately after operation. 

 

It is recommended that you lay the adapter on the floor or desk so that the green light is 
visible. This will alert you if the adapter should accidentally go off due to external effects. If 
for any reason the green light goes off, disconnect the AC power cord from the wall for a 
period of ten seconds, and then reconnect the power cord. 

 

Japan Only: Use only the Dell-provided AC power cable with the AC adapter. Use of any 
other power cable may damage the device or AC adapter or may present risk of fire or 
electric shock. 

 
 
 
 
 
 
 
 
 

Summary of Contents for S2422HGB

Page 1: ... 1 Simplified Service Manual S2422HGB Version 01 Date 2020 12 08 ...

Page 2: ... 2 Content Index 1 General Safety Instructions 3 1 1 SAFETY General Safety 3 1 2 SAFETY General Power Safety 5 2 Disassembly SOP 6 3 Assembly SOP 9 ...

Page 3: ...or place equipment so close together that it is subject to recalculated or preheated air NOTE Review the weight limits referenced in your computer documentation before placing a monitor or other devices on top of your computer Ensure that nothing rests on your equipment s cables and that the cables are not located where they can be stepped on or tripped over Ensure that all cables are connected to...

Page 4: ...omponents inside your equipment Under certain conditions ESD may build up on your body or an object such as a peripheral and then discharge into another object such as your computer To prevent ESD damage you should discharge static electricity from your body before you interact with any of your equipment s internal electronic components such as a memory module You can protect against ESD by touchi...

Page 5: ...as risk of electric shock and or fire Ensure that the ground prong of the power plug is inserted into the mating ground contact of the power strip Be sure to grasp the plug not the cable when disconnecting equipment from an electric socket If your equipment uses an AC adapter Use only the Dell provided AC adapter approved for use with this device Use of another AC adapter may cause a fire or explo...

Page 6: ...ing table 2 Screw driver 3 Gloves 4 Cleaning cloth 5 ESD protection 6 S2422HGB Curve Sponge Jig Item Picture Operation Tool Notes 1 To remove the stand 1 Place the monitor on S2422HGB Curve Sponge Jig 2 Press and hold the stand release button 3 Lift the stand up and away from the monitor S2422HGB Curve Sponge Jig Panel and whole monitor head must be put on S2422HGB curve sponge jig to avoid panel ...

Page 7: ...m I F BD and tear off it from Main SHD to take off Rear Cover Scraper bar 4 1 Remove LENS BD PWR BTN BD FFC from I F BD 2 Remove Backlight wire from SPS BD 3 Unlock 4 screws on Main SHD Screw driver Torsion of screw 4 5 0 5Kg 5 1 Remove conductive cloth and acetate tape from panel 2 Unplug LVDS FFC cable and WIRE 6P 10P from panel 3 Take off Main SHD from Panel ...

Page 8: ...S BD 7 1 Unlock 8 PCBA screws Screw driver Torsion of screw 8 5 1 0kg 8 1 Disassemble I F BD from Main SHD and remove SPS BD wire from I F BD 2 Disassemble SPS BD from Main SHD 3 Remove LVDS FFC cable and WIRE 6P 10P from I F BD ...

Page 9: ... bellow 7 Working table 8 Screw driver 9 Glove 10 Cleaning cloth ESD protection Item Picture Operation Tools Notes 1 1 Insert LVDS FFC cable and WIRE 6P 10P into I F BD 2 Assemble SPS BD to Main SHD 3 Insert SPS BD wire to I F BD and assemble I F BD to Main SHD 4 Lock 8 PCBA screws Screw driver Torsion of screw 8 5 1 0kg 2 1 Assemble Mylar to SPS BD ...

Page 10: ...2HGB Curve Sponge Jig Panel and whole monitor head must be put on S2422HGB curve sponge jig to avoid panel damage It is not allowed to place the front side of panel and monitor head on a flat surface 4 1 Place Main SHD on Panel 2 Insert Backlight wire to SPS BD 3 Lock 4 screws to fix Main SHD on Panel 4 Insert LENS BD PWR BTN BD FFC to I F BD 5 1 Insert CTRL BD FFC into I F BD and paste it on Main...

Page 11: ...e stand with monitor head 1 Align and place the stand riser on the stand base 2 Open the screw handle at the bottom of the stand base and turn it clockwise to secure the stand assembly 3 Close the screw handle 4 Insert the tabs on the stand riser into the slots on the display back cover and lower the stand assembly to snap it into place ...

Reviews: