Table 22. Library error codes (continued)
Code (H)
Description
Panel Indication
Action Required
00C0
accessor operation disabled
because a cartridge magazine was
removed. Suspect the magazine
set sensor.
CHK 00C0
1.
Confirm that the magazine is closed.
2.
Cycle the power supply and try again.
v
If the problem is corrected, run Library
Verify before normal library operations
resume.
v
If the problem persists, see “Contacting
Dell technical support” on page 111.
00C8
Centering calibration error #1.
During centering calibration,
centering sensor OFF condition
could not be detected. Suspect the
centering sensor or P motor.
CHK 00C8
Cycle the power supply and try again.
v
If the problem is corrected, run Library Verify
before normal library operations resume.
v
If the problem persists, see “Contacting Dell
technical support” on page 111.
00C9
Centering calibration error #2.
During centering calibration,
centering sensor ON condition
could not be detected. Suspect the
centering sensor, X motor, or P
motor.
CHK 00C9
00D0
Checksum error detected during
firmware update.
CHK 00D0
1.
Confirm the firmware file version.
2.
Reinstall the firmware file.
3.
Cycle the power supply and try again.
v
If the problem is corrected, run Library
Verify before normal library operations
resume.
v
If the problem persists, see “Contacting
Dell technical support” on page 111.
00D1
Firmware ID error detected
during firmware update.
CHK 00D1
00D2
Boot information error detected
during firmware update.
CHK 00D2
00D3
Bar code reader is not in
maintenance mode during bar
code reader firmware update
(operation interrupted). Suspect
the bar code reader cable
connection.
CHK 00D3
1.
Initiate an inventory. See “Conducting a
library inventory” on page 56 (Operator
Panel) or “Conducting a library inventory”
on page 71 (Web User Interface).
2.
Cycle the power supply and try again.
v
If the problem is corrected, run Library
Verify before normal library operations
resume.
v
If the problem persists, see “Contacting
Dell technical support” on page 111.
00D9
Magazine failed to unlock.
Suspect the magazine or
magazine sensor.
CHK 00D9
1.
Cycle the power supply and try again.
2.
Manually unlock the magazine, remove the
magazine from the library, and inspect it for
damage.
v
If not damaged, return it to the library and
run Library Verify before normal library
operations resume.
v
If damaged, replace the magazine.
00DA
I/O Station failed to unlock.
Suspect the magazine or
magazine sensor.
CHK 00DA
122
Dell PowerVault TL1000 Tape Autoloader: User's Guide
Summary of Contents for PowerVault TL1000
Page 1: ...Dell PowerVault TL1000 Tape Autoloader User s Guide IBM ...
Page 2: ......
Page 4: ...iv Dell PowerVault TL1000 Tape Autoloader User s Guide ...
Page 6: ...vi Dell PowerVault TL1000 Tape Autoloader User s Guide ...
Page 12: ...xii Dell PowerVault TL1000 Tape Autoloader User s Guide ...
Page 18: ...xviii Dell PowerVault TL1000 Tape Autoloader User s Guide ...
Page 30: ...12 Dell PowerVault TL1000 Tape Autoloader User s Guide ...
Page 108: ...90 Dell PowerVault TL1000 Tape Autoloader User s Guide ...
Page 128: ...110 Dell PowerVault TL1000 Tape Autoloader User s Guide ...
Page 162: ...144 Dell PowerVault TL1000 Tape Autoloader User s Guide ...
Page 166: ...148 Dell PowerVault TL1000 Tape Autoloader User s Guide ...
Page 168: ...150 Dell PowerVault TL1000 Tape Autoloader User s Guide ...
Page 186: ...168 Dell PowerVault TL1000 Tape Autoloader User s Guide ...
Page 190: ...172 Dell PowerVault TL1000 Tape Autoloader User s Guide ...
Page 191: ......
Page 192: ...IBM Printed in USA ...