he Dell PowerVault MD3000 storage array is designed 
to provide flexible, high-performance, highly scal-
able RAID storage without compromising data integ-

rity. Its integration of two high-performance RAID controllers, 
Dell Modular Disk Storage Manager software, and automatic 
event monitoring helps reduce total cost of ownership and 
maximize data protection.

The PowerVault MD3000 external RAID array can sup-

port up to forty-five 3.0 Gbps Serial Attached SCSI (SAS) 
disks  and  includes  redundant  power  supplies  and  fans. 
Connectivity between host servers and the storage is pro-
vided  by  two  Dell  SAS  5/E  host  bus  adapters  (HBAs).  
The  PowerVault  MD3000  is  designed  primarily  for  high- 
performance  two-node  clusters;  however,  its  dual-port 
RAID  controllers  can  also  provide  shared  nonredundant 
storage for up to four servers. Other key features include 
the following:

• 

Mirrored  data  cache  of  up  to  512  MB  on  each  RAID 
controller

• 

In-band and out-of-band management using Dell Modular 
Disk Storage Manager

• 

Redundant, hot-swappable components and virtual disk 
failover

• 

Transparent failover for clustered operating systems to 
help maximize data protection

• 

Virtual disk snapshot and virtual disk copy creation

• 

RAID level migration, capacity expansion, consistency 

checks,  and  Self-Monitoring,  Analysis,  and  Reporting 
Technology (SMART)

Figure  1  compares  PowerVault  MD3000  features  with 

those of the PowerVault MD1000.

Configuration options for the Dell PowerVault MD3000

Administrators can configure the PowerVault MD3000 as 
part of a nonredundant configuration or a redundant clus-
ter configuration. Nonredundant configurations are recom-
mended  only  for  noncritical  data  storage;  this  type  of 
configuration provides only a single data path, meaning a 
failed  or  removed  cable,  HBA,  or  RAID  controller  could 
cause the storage path to fail. 

Redundant cluster configurations, in contrast, provide high 

availability for critical data and depend primarily on physical 
connectivity and the host multipath software. If a component 
fails or an error occurs on the data path to the primary RAID 
controller,  the  multipath  driver—Microsoft

®

  Multipath  I/O 

(MPIO)  on  Microsoft  Windows

®

  operating  systems  and 

Multipath Proxy (MPP) on Linux

®

 operating systems—fails over 

virtual disk ownership to the secondary RAID controller for I/O 
processing, helping ensure host data access.

The PowerVault MD3000 supports two redundant cluster 

configurations:

• 

Single port:

 Administrators can use this mode with a 

single storage path and single-port RAID controllers (see 

Related Categories:

Backup, recovery, and 

archiving (BURA)

Dell PowerVault storage

Direct attach storage (DAS)

Serial Attached SCSI (SAS)

Storage

Visit 

www.dell.com/powersolutions

 

for the complete category index.

Exploring the Dell 

PowerVault MD3000

Storage System

The Dell

 PowerVault

 MD3000 external RAID enclosure allows 

multiple servers to access a shared pool of expandable storage, 
helping enterprises avoid the costs and complexities of internal 
storage. This article outlines the hardware, configuration, and 
management features of this storage system.

By Manjusha GopakuMar

Vishal kadaM

paul Winston

reprinted from 

Dell Power Solutions,

 May 2007. Copyright © 2007 dell inc. all rights reserved. rev. 2.

Storage

DELL 

POWER

 SOLUTIONS  |

  May 2007

1

Summary of Contents for PowerVault MD3000

Page 1: ...redundant configuration or a redundant clus ter configuration Nonredundant configurations are recom mended only for noncritical data storage this type of configuration provides only a single data path meaning a failed or removed cable HBA or RAID controller could cause the storage path to fail Redundantclusterconfigurations incontrast providehigh availability for critical data and depend primarily...

Page 2: ...nd man agement is available when client systems can connect to the PowerVault MD3000 using Ethernet and the Modular DiskStorage Manager management station package is installed The Modular DiskStorage Manager CLI gives administrators direct access to a script engine utility that reads commandsand runs script files Tasks administrators can perform using the CLI include the following Create script co...

Page 3: ...ual disk must be a standard virtual disk in the storage array Snapshots are typically created so that software such as a backup application can access them while the source virtual disk remains accessible to hosts Modular Disk Storage Manager supports application aware snapshots which are recom mended for transaction based applications where all transaction operations must be com pleted for transa...

Page 4: ...ot create another storage partition LUN masking is implemented using storage partitions Administrators can use single storage parti tions or multiple storage partitions for different purposes Single storage partitions are useful when only one attached host is accessing all of the virtual disks in the storage array or when all attached hosts share access to all virtual disks on the storage array th...

Reviews: