NOTE:
The release trigger and handle for node B is on the top left. The release trigger and handle for node A is on the
bottom right.
CAUTION:
Removing the incorrect node will lead to loss of system power and cached data will be lost.
Figure 68. Disengaging the locking mechanism for node B
5. Before removing the node, ensure that the wire bail is properly secured to the power supply cable of the other node to
prevent accidental loss of power and cache.
6. Use the release handle to pull the node outward enough to grasp the sides with both hands. Then, with both hands
supporting the node, pull the node fully out of the enclosure.
Figure 69. Removing the node
7. Place the node on a clean, flat, static-free work surface.
Remove the top cover from the node
Steps
1. While pushing down the two blue release buttons, slide the top cover towards the rear of the system, until it stops.
2. Lift the top cover upward, and remove it from the node.
64
Base enclosure service procedures