Installing the power interposer board
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1.
.
2.
Follow the procedure listed in
Before working inside your system
3.
Remove the cooling shroud.
NOTE: If applicable, close the expansion card latch on the cooling shroud to release the full
length card.
4.
If applicable, disconnect the power or data cables from expansion card (s).
5.
If applicable, remove the expansion card riser
6.
Remove the internal hard drive carrier.
7.
Remove the internal hard drive cage.
Steps
1.
Align the locking slots on the power interposer board with the hooks on the power supply cage and
slide it into place.
2.
Route the power cables as applicable, and connect the power cables to the system board and hard
drive backplane.
3.
Install the power supply module(s) in their original locations.
Next steps
1.
If applicable, install the PCIe expansion card riser.
2.
If applicable, connect the required power or data cables to the expansion card(s).
3.
Install the internal hard drive cage.
4.
Install the internal hard drive carrier.
5.
Reinstall the cooling shroud.
6.
If applicable open the expansion card latch on the cooling shroud to secure the full length
expansion card.
7.
Follow the procedure listed in
After working inside your system
.
Related Tasks
Removing the cooling shroud
Removing the (optional) dual riser module
Installing the (optional) dual riser module
Installing the cooling shroud
120