You can also download it from the Dell Support website to troubleshoot and fix your computer when it fails to boot into their
primary operating system due to software or hardware failures.
For more information about the Dell SupportAssist OS Recovery, see
Dell SupportAssist OS Recovery User's Guide
at
www.dell.com/serviceabilitytools
. Click
SupportAssist
and then, click
SupportAssist OS Recovery
.
Backup media and recovery options
It is recommended to create a recovery drive to troubleshoot and fix problems that may occur with Windows. Dell proposes
multiple options for recovering Windows operating system on your Dell PC. For more information. see
.
Real Time Clock—RTC reset
The Real Time Clock (RTC) reset function allows you or the service technician to recover the recently launched model systems
from
No POST/No Boot/No Power
situations. You can initiate the RTC reset on the system from a power-off state only if it
is connected to AC power. Press and hold the power button for 30 seconds. The system RTC reset occurs after you release the
power button.
NOTE:
If AC power is disconnected from the system during the process or the power button is held longer than 40
seconds, the RTC reset process gets aborted.
The RTC reset will reset the BIOS to defaults, un-provision Intel vPro and reset the system date and time. The following items
are unaffected by the RTC reset:
●
Service Tag
●
Asset Tag
●
Ownership Tag
●
Admin Password
●
System Password
●
HDD Password
●
Key Databases
●
System Logs
●
TPM on and TPM Enabled settings are unaffected by RTC Reset and should not cause BitLocker issues
NOTE:
The IT administrator's vPro account and password on the system will be un-provisioned. The system needs to go
through the setup and configuration process again to reconnect it to the vPro server.
The below items may or may not reset based on your custom BIOS setting selections:
●
Boot List
●
Enable Legacy Option ROMs
●
Secure Boot Enable — Allow BIOS Downgrade
WiFi power cycle
About this task
If your computer is unable to access the internet due to WiFi connectivity issues a WiFi power cycle procedure may be
performed. The following procedure provides the instructions on how to conduct a WiFi power cycle:
NOTE:
Some ISPs (Internet Service Providers) provide a modem/router combo device.
Steps
1. Turn off your computer.
2. Turn off the modem.
3. Turn off the wireless router.
4. Wait for 30 seconds.
5. Turn on the wireless router.
Troubleshooting
135
Summary of Contents for OptiPlex 7760
Page 1: ...Precision 7760 Service Manual Regulatory Model P44E Regulatory Type P44E002 July 2021 Rev A01 ...
Page 17: ...For computers without SSD door configuration Removing and installing components 17 ...
Page 25: ...Removing and installing components 25 ...
Page 29: ...Removing and installing components 29 ...
Page 74: ...74 Removing and installing components ...
Page 87: ...Removing and installing components 87 ...
Page 97: ...Removing and installing components 97 ...
Page 98: ...98 Removing and installing components ...