Layer 2 Switching Commands
491
the interface continues to encounter errors (from any listed cause), it may be
placed back in the diag-disable state and the interface will be disabled (link
down).
Interfaces in the disabled state due to a listed cause may be manually
recovered by entering the no shutdown command for the interface.
Interfaces in the disabled state may be manually shut down. These interfaces
will not be recovered.
Auto-recovery applies to physical interfaces and link aggregation groups.
Command History
Implemented in version 6.3.0.1 firmware.
Example
The following example enables auto-recovery for all causes.
console(config)#errdisable recovery cause all
errdisable recovery interval
Use the
errdisable recovery interval
command to configure the interval for
error recovery of interfaces disabled due to any cause. Use the
no
form of the
command to reset the interval to the default.
Syntax
errdisable recovery interval
interval
• interval — The interval in seconds. The range is 30-3600 seconds. The
default is 300 seconds.
Default Configuration
The default interval is 300 seconds. Range 30-3600 seconds.
No recovery causes are enabled by default.
Command Mode
Global Configuration mode
Summary of Contents for N1100-ON
Page 2: ......
Page 4: ......
Page 258: ...Using the CLI 258 ...
Page 488: ...Layer 2 Switching Commands 488 Operational State Querier Operational version 1 ...
Page 656: ...Layer 2 Switching Commands 656 10 ...
Page 1128: ...Audio Visual Bridging Commands 1128 ...
Page 1186: ...Data Center Technology Commands 1186 ...
Page 1435: ...Layer 3 Routing Commands 1435 Number of Joins 7 Number of Groups 1 ...
Page 2330: ......
Page 2331: ...www dell com support dell com Printed in the U S A ...
Page 2332: ......