Chapter 5.
UBox Components
5-7
5.2.6.
UBox PSU Numbering
Rear view
Mark
Description
I
UBox PSU 0
J
UBox PSU 1
K
UBox PSU 2
L
UBox PSU 3
There are up to four PSUs installed in a UBox, according to the voltage range
and the UBox model.
System
configuration
Voltage
range
Population rule
Redundancy
Two UNB modules
100-110V
•
PSU 0
•
PSU 1
•
PSU 2 or 3
2+1 redundancy
200-240V
•
PSU 0
•
PSU 1
1+1 redundancy
Four UNB modules
100-110V
•
PSU 0
•
PSU 1
•
PSU 2
•
PSU 3
3+1 redundancy
200-240V
•
PSU 0
•
PSU 1
•
PSU 2 or 3
2+1 redundancy
Important
Regardless of the system configuration, voltage range and
PSU redundancy, the UBox cannot function if both PSU
0