Identifier
GUID-98F27B1C-9F09-48EC-83D7-FC85C825E6A4
Status
Released
Replacing the I/O board
WARNING:
Before working inside your computer, read the safety information that shipped with your computer and follow the
steps in
Before working inside your computer
. After working inside your computer, follow the instructions in
. For more safety best practices, see the Regulatory Compliance home page at
Identifier
GUID-41224B55-62D6-4B12-A0F4-77D3367B5292
Status
Released
Procedure
1
Place the I/O board on the palm-rest and keyboard assembly, and then align the screw holes on the I/O board with the screw holes on
the palm-rest and keyboard assembly.
2
Replace the two screws (M2x3) that secure the I/O board to the palm-rest and keyboard assembly.
3
Slide the fingerprint-reader cable into the connector on the I/O board and close the latch to secure the cable.
4
Slide the I/O-board cable into the connector on the I/O board and close the latch to secure the cable.
5
Adhere the tape that secures the I/O-board cable to the I/O board.
Identifier
GUID-EE31644C-8CF0-4069-89C9-C081096D205E
Status
Released
Post-requisites
Replace the
.