Deploying FCoE (FIP Snooping) on Dell Force 10 MXL
51
Flow of vPC configuration on Cisco Nexus 5000 series switches
Figure 44.
Enable features
Connect to first
Cisco Nexus 5000
Series Switch
Configure vpc
domain and peer-
keepalive
Configure the vPC
peer-link
feature vpc
feature lacp
vpc domain 1
role priority 1000
peer-keepalive destination
172.25.188.61
interface po4096
vpc peer-link
switchport mode trunk
interface ethernet 1/29-32
channel-group 4096 mode
active
Configure
downlink ports
and final vpc
entry on peer-link
interface ethernet 1/1-
2
channel-group 1
interface ethernet 1/
17-18
channel-group 2
interface po4096
vpc 100
Connect to second Cisco Nexus 5000 Series
Switch and perform same steps with on
destination and role priority changes
feature vpc
feature lacp
vpc domain 1
role priority 2000
peer-keepalive destination 172.25.188.60
interface po4096
vpc peer-link
switchport mode trunk
switchport trunk allowed vlan 1-100
interface ethernet 1/29-32
channel-group 4096 mode active
interface po1
switchport mode trunk
vpc 1
interface po2
switchport mode trunk
vpc 2
interface ethernet 1/1-2
channel-group 1
interface ethernet 1/17-18
channel-group 2
Configure downlink LAG/
PortChannel
interface po1
switchport mode trunk
vpc 1
interface po2
switchport mode trunk
vpc 2