Alternatively, run the
sg_inq /dev/sciniX
SCSI query command (requires that
the sg3_utils be installed on the Linux host). The result of this command includes the
EMC volume ID at the bottom of the output, as illustrated:
Note:
The product identification remains as ScaleIO (not VxFlex OS).
Port usage and changing default ports
The following table lists the TCP ports that are used by VxFlex OS. Prior to installing
or upgrading a system, ensure that these ports are not in use by other processes.
If they are in use, either free them or change them to another available port.
Note:
When using a firewall in the switch, you must enable the relevant ports and
protocols for proper communications between the AMS and the host, SVMs and
iDRAC. See "iDRAC access ports".
Table 33 Default ports
Port used by
Port #
Protocol File to change
Field to modify
(or to add, if it
does not exist)
Notes
AMS and MDM
listener
6611
Protobuf
over TCP
Note:
Cannot be modified, and must be available
MDM Cluster
member
9011
Protobuf
over TCP
/opt/emc/
scaleio/mdm/cfg/
conf.txt
actor_cluste
r_port
=
<NEW_
PORT>
SVM/host ADC
(auto-detect
client)
33333
UDP
Note:
Cannot be modified, and must be
available
The ADC uses this port to listen to
broadcasts and set IP requests from
the ADS during the discovery
process.
AMS ADS
(auto-detect
server)
33833
UDP
Note:
Cannot be modified, and must be
available
The AMS uses this port to transmit
discovery broadcast requests and
set IPs to SVMs and hosts.
SDS listener
7072
Proprietar
y protocol
over TCP
/opt/emc/
scaleio/sds/cfg/
conf.txt
tgt_port
=
<NE
W_PORT>
SDCs connect through this port for
data communications and to the
MDM for meta-data
communications. When multiple
SDSs are installed on the same
physical server, use ports 7072+
x
,
where
x
is the index of the SDS (for
example, 70721, 70722).
LIA listener
9099
Protobuf
over TCP
/opt/emc/
scaleio/lia/cfg/
conf.txt
lia_port
=
<NE
W_PORT>
The VxFlex OS Installer connects to
the LIA to perform installation and
maintenance-related operations.
Common Tasks
Dell EMC VxFlex Ready Node AMS User Guide
255
Summary of Contents for EMC VxFlex Ready Node
Page 1: ...Dell EMC VxFlex Ready Node Version 3 x AMS User Guide P N 302 005 733 REV 02 June 2019 ...
Page 10: ...Contents 10 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 12: ...Figures 12 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 14: ...Tables 14 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 18: ...Introduction 18 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 24: ...Introduction to VxFlex Ready Node 24 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 80: ...Architecture 80 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 110: ...VxFlex OS Performance Fine Tuning 110 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 130: ...Managing and Monitoring 130 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 156: ...Managing System Objects 156 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 182: ...Security Management 182 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 188: ...Monitoring the System using the VxFlex OS GUI 188 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 252: ...Reference 252 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 274: ...Common Tasks 274 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 292: ...System events 292 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 324: ...SNMP Trap Support 324 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 348: ...DTK Hardware Update Bootable ISO 348 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 354: ...Glossary 354 Dell EMC VxFlex Ready Node AMS User Guide ...