Task
Command
l
scli --set_rmcache_usage --
protection_domain_name <domain NAME> --
storage_pool_name <pool NAME> --use_rmcache
[--dont_use_rmcache]
l
scli --enable_sds_rmcache [--
disable_sds_rmcache] --sds_name <NAME>
Note:
Using this command would be required for every
SDS in the cluster.
To increase the amount of
Read RAM cache
Run the following command:
scli --set_sds_rmcache_size ((--sds_id <ID> | --
sds_name <NAME> | --sds_ip <IP> [--sds_port
<PORT>]) | (--protection_domain_id <ID> | --
protection_domain_name <NAME>)) --
rmcache_size_mb <SIZE> [--i_am_sure]
Where --rmcache_size_mb is the size of rmcache in MB, and
the range is between 128MB-300GB.
It is important to ensure that Read RAM cache is enabled at all
levels (PD, SP, and SDS). When rmcache is properly enabled,
query output will look like this:
Read Flash Cache settings for SDS
Read Flash Cache is available from version 2.x and later. This feature is a Read Cache
used to increase read performance and buffers writes to increase the performance of
Read-after-Write I/Os. It allows users to create and configure an "RFcache" device
for any SSD or Flash card. VxFlex OS will cache user data depending on the mode
selected. This feature can greatly improve performance for specific workloads. The
RFcache device is also referred to as an accelerated device.
To create an RFcache device and configure it, use the following steps:
1. Create an RFcache device (Recommendation: create 1 device per SDS).
scli --add_sds_rfcache_device --sds_name <NAME> --
rfcache_device_path <device_path> --rfcache_device_name
<RFcache device NAME>
VxFlex OS performance fine-tuning
116
Dell EMC VxFlex Ready Node AMS User Guide
Summary of Contents for EMC VxFlex Ready Node
Page 1: ...Dell EMC VxFlex Ready Node Version 3 x AMS User Guide P N 302 005 733 REV 02 June 2019 ...
Page 10: ...Contents 10 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 12: ...Figures 12 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 14: ...Tables 14 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 18: ...Introduction 18 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 24: ...Introduction to VxFlex Ready Node 24 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 80: ...Architecture 80 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 110: ...VxFlex OS Performance Fine Tuning 110 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 130: ...Managing and Monitoring 130 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 156: ...Managing System Objects 156 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 182: ...Security Management 182 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 188: ...Monitoring the System using the VxFlex OS GUI 188 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 252: ...Reference 252 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 274: ...Common Tasks 274 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 292: ...System events 292 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 324: ...SNMP Trap Support 324 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 348: ...DTK Hardware Update Bootable ISO 348 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 354: ...Glossary 354 Dell EMC VxFlex Ready Node AMS User Guide ...