Table 10 Supported video resolution options
Resolution
Refresh rate (Hz)
Color depth (bits)
1024 x 768
60
8, 16, 32
1280 x 800
60
8, 16, 32
1280 x 1024
60
8, 16, 32
1360 x 768
60
8, 16, 32
1440 x 900
60
8, 16, 32
1600 x 900
60
8, 16, 32
1600 x 1200
60
8, 16, 32
1680 x 1050
60
8, 16, 32
1920 x 1080
60
8, 16, 32
1920 x 1200
60
8, 16, 32
Note:
1920 x 1080 and 1920 x 1200 resolutions are supported only in reduced blanking mode.
Environmental specifications
Note:
For additional information about environmental certifications, see the
Product Environmental Datasheet
located with the Manuals & Documents at
When the system is in continuous operation (for altitude less than 950 m or 3117 ft), the temperature specification
ranges 10 °C–35°C (50–95°F) with no direct sunlight on the equipment. When the system is not in operation, the
temperature specification is –40 °C–65°C (–40–149°F). For more information about fresh air, see the Expanded
Operating Temperature section. The Maximum temperature gradient for both operation and nonoperational systems is
20°C/h (36°F/h). Information about fresh air specification is described in the Expanded Operating Temperature
section.
Table 11 Temperature specifications
Temperature
Specifications
Storage
–40–65°C (–40 °F–149°F)
Continuous operation (for altitude less than 950 m
or 3117 ft)
10–35°C (50 °F–95°F) with no direct sunlight on the equipment
Maximum temperature gradient (operating and
storage)
20°C/h (36°F/h)
For a nonoperational system, the ambient relative humidity ranges from 5% to 95% with 33°C (91°F) maximum dew
point. Atmosphere must be noncondensing at all times. For an operational system, the ambient relative humidity ranges
from 10% to 80% with 29°C (84.2°F) maximum dew point.
Table 12 Relative humidity specifications
Relative humidity
Specifications
Storage
5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be
noncondensing at all times.