0 — not blinking (default)
•
1 — blinking
racadm raid <
operation
> <component FQDD>
, where the
operation
value is
blink
or
unblink
, and the FQDD is for
the component's physical disk drive, virtual disk and enclosures.
Configuring CMC Properties
You can configure CMC properties such as power budgeting, network settings, users, and SNMP and email alerts using the web
interface or RACADM commands.
Configuring iDRAC Launch Method Using CMC Web Interface
To configure the iDRAC launch method from the
General Chassis Settings
page:
1.
In the left pane, click
Chassis Overview
→
Setup
.
The
General Chassis Settings
page is displayed.
2.
In the drop-down menu for the
iDRAC Launch Method
property, select
IP Address
or
DNS
.
3.
Click
Apply
.
NOTE: A DNS-based launch is used for any particular iDRAC only if:
•
The chassis setting is DNS.
•
CMC has detected that the specific iDRAC is configured with a DNS name.
Configuring iDRAC Launch Method Using RACADM
To update CMC firmware using RACADM, use the
cfgRacTuneIdracDNSLaunchEnable
subcommand. For more information,
see the
Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide
available at
dell.com/
support/manuals
.
Configuring Login Lockout Policy Attributes Using CMC Web Interface
NOTE: To perform the following tasks, you must have Chassis Configuration Administrator privilege.
The
Log in Security
enables you to configure the IP range attributes for CMC login using the CMC web interface. To configure the
IP range attributes using CMC web interface:
1.
In the left pane, go to
Chassis Overview
and click
Network
→
Network
.
The
Network Configuration
page is displayed.
2.
In the IPv4 Settings section, click
Advanced Settings
. Alternatively, to access the
Log in Security
page, in the left pane, go to
Chassis Overview
, click
Security
→
Log in
.
The
Log in Security
page is displayed.
3.
To enable the user blocking or IP blocking feature, in the
Login Lockout Policy
section, select
Lockout by User Name
or
Lockout by IP Address (IPV4)
.
The options to set the other login lockout policy attributes are activated.
4.
Enter the required values for login lockout policy attributes in the activated fields —
Lockout Fail Count
,
Lockout Fail Window
,
and
Lockout Penalty Time
. For more information, see the
CMC Online Help
.
5.
To save these settings, click
Apply
.
Configuring Login Lockout Policy Attributes Using RACADM
You can use RACADM to configure the Login lockout policy attributes for the following features:
•
User blocking