Figure 45. Installing the cooling fan assembly
Next step
Follow the procedure listed in
After working inside your system
Flex bays
Your system's flex bay supports 16 x 2.5 inch SAS or SATA drives or 8 x NVMe (2.5 inch) drives.
Removing a NVMe drive bay or flex bay
Prerequisites
NOTE:
The procedure to remove the flex bay is identical to removing the NVMe drive bay.
1
Follow the safety guidelines listed in
2
Follow the procedure listed in
Before working inside your system
.
3
Disconnect the slim optical-drive and the backplane cables.
4
Remove the backplane from NVMe drive bay or the flex bay.
Steps
1
Using the Phillips #2 screwdriver, remove the two screws that secure the NVMe drive bay to the system.
2
Push the release latch down and slide the NVMe drive bay out of the system.
100
Installing and removing system components