3
If applicable, remove the air shroud.
Steps
1
Using a Torx #T30 screwdriver, loosen the screws on the heat sink in the order below:
a Loosen the first screw three turns.
b Loosen the second screw completely.
c Return to the first screw and loosen it completely.
NOTE:
It is normal for the heat sink to slip off the blue retention clips when the screws are partially
loosened, continue to loosen the screw(s).
2
Pushing both blue retention clips simultaneously, lift the out of the system.
3
Set the PHM aside with the processor side facing up.
Next step
Install the PHM.
Removing the processor from the processor and heat sink
module
Prerequisites
NOTE:
Only remove the processor from the processor and heat sink module if you are replacing the processor or heat sink. This
procedure is not required when replacing a system board.
1
Follow the safety guidelines listed in
2
Follow the procedure listed in
Before working inside your system
.
3
Remove the air shroud.
4
Remove the processor and heat sink module.
Steps
1
Place the heat sink with the processor side facing up.
2
Insert a flat blade screwdriver into the release slot marked with a yellow label. Twist (do not pry) the screwdriver to break the thermal
paste seal.
3
Push the retaining clips on the processor bracket to unlock the bracket from the heat sink.
Installing and removing system components
65