Figure 69. Installing a power supply unit blank
Removing a power supply unit
Prerequisites
CAUTION:
The system requires one power supply unit (PSU) for normal operation. On power-redundant
systems, remove and replace only one PSU at a time in a system that is powered on.
1. Follow the safety guidelines listed in
.
2. Disconnect the power cable from the power outlet and from the PSU you intend to remove.
3. Remove the cable from the strap on the PSU handle.
4. Unlatch and lift the optional cable management arm if it interferes with the PSU removal.
For information about the cable management arm, see the system’s rack documentation at
.
Steps
Press the release latch, and holding the PSU handle slide the PSU out of the PSU bay.
Figure 70. Removing a power supply unit
Next steps
1.
Replace the power supply units
or
Installing and removing system components
67