Next steps
1.
.
2. Follow the procedure listed in the
After working inside your system
.
Liquid cooling heat sink with liquid leak sensor
Removing the liquid cooling heat sink with liquid leak sensor cover
Prerequisites
1. Follow the safety guidelines listed in the
.
2. Follow the procedure listed in the
Before working inside your system
.
.
NOTE:
The heat sink and processor are too hot to touch for some time after the system has been powered down. Allow the
heat sink and processor to cool down before handling them.
Steps
1. Using a Phillips #1 screw driver, remove the screws that secure the liquid cooling heat sink with liquid leak sensor cover.
Figure 53. Removing the liquid cooling heat sink with liquid leak sensor cover
2. Remove the liquid cooling heat sink with liquid leak sensor cover.
NOTE:
If applicable, route and engage the liquid cooling heat sink with liquid leak sensor tubes with the groves in the
liquid cooling heat sink bracket.
Next steps
1. If you are removing a faulty liquid cooling heat sink with liquid leak sensor,
replace the liquid cooling heat sink with liquid leak
, if not,
.
2. If you are replacing the liquid cooling heat sink with a standard heat sink
, if not,
.
56
Installing and removing system components