Figure 97. Installing optical drive
3. Connect the power and data cables to the connector on the optical drive.
NOTE:
Route the cable properly to prevent it from being pinched or crimped.
4.
Next steps
1. Follow the procedure listed in
After working inside your system
on page 26.
Power supply units
NOTE:
For more information, see the PowerEdge R440 Technical Specs at
www.dell.com/poweredgemanuals
.
CAUTION:
If two PSUs are installed, both the PSUs must have the same type of label. For example, Extended
Power Performance (EPP) label. Mixing PSUs from previous generations of PowerEdge servers is not
supported, even if the PSUs have the same power rating. Mixing PSUs will result in mismatch condition or
failure to turn the system on.
NOTE:
When two identical PSUs are installed, power supply redundancy (1+1 – with redundancy or 2+0 – without
redundancy) is configured in system BIOS. In redundant mode, power is supplied to the system equally from both PSUs
when Hot Spare is disabled. When Hot Spare is enabled, one of the PSUs is put into the sleep mode when system utilization
is low in order to maximize efficiency.
NOTE:
If two PSUs are used, they must be of the same maximum output power.
Removing a power supply unit blank
Prerequisites
Follow the safety guidelines listed in
.
Steps
If you are installing a second power supply unit, remove the power supply unit blank in the bay by pulling the blank outward.
CAUTION:
To ensure proper system cooling, the power supply unit blank must be installed in the second power
supply unit bay in a non-redundant configuration. Remove the power supply unit blank only if you are installing a
second power supply unit.
Installing and removing system components
97