2-6
Dell Dimension XPS R
xxx
Systems Service Manual
5HFRQQHFW WKH FRPSXWHU DQG DQ\ DWWDFKHG SHULSKHUDOV WR WKHLU
SRZHU VRXUFHV DQG WXUQ WKHP RQ
Does the problem appear to be resolved?
Yes.
No further steps are necessary.
No.
Proceed to the next sections, “Eliminating Resource Conflicts,” “Run-
ning the Dell Diagnostics,” and “Getting Help.”
(OLPLQDWLQJ5HVRXUFH&RQIOLFWV
Devices within or connected to the computer may require dedicated memory
spaces, interrupt levels, or DMA channels, all of which must be allocated dur-
ing installation of the devices. Because devices may be installed at different
times, it is possible that the same resource is assigned to two or more
devices.
Resource conflicts can result in disorderly or erratic system operation or failure
of the system to operate at all. If you suspect that resource conflicts might
exist, check the system using the Microsoft
®
Windows
®
95 Device Manager,
and reassign the resources as necessary. See “Advanced Expansion Sub-
system” in Chapter 1 for information on the Device Manager. See “Interrupt
Assignments” in Chapter 1 to help identify possible conflicts. Also review the
documentation provided with any installed expansion cards and other devices
for additional interrupt information for the specific devices.
Online troubleshooting tools (OTT), flowcharts, and procedures for diagnosing
problems are available on the Dell World Wide Web site at
http://www.dell.com
.
5XQQLQJWKH'HOO'LDJQRVWLFV
The Dell Diagnostics (included with the computer) contain tests that aid in
troubleshooting all major components of the computer system.
&$87,21 7R SUHYHQW GDPDJH WR WKH RULJLQDO GLDJQRVWLFV GLVNHWWH
DOZD\V XVH D EDFNXS FRS\ RI WKH GLDJQRVWLFV GLVNHWWH ZKHQ VHUYLFLQJ
D XVHU·V FRPSXWHU 'HOO UHFRPPHQGV WKDW XVHUV PDNH VHYHUDO FRSLHV
RI WKLV GLVNHWWH WR HQVXUH WKDW RQH LV DOZD\V DYDLODEOH
To start the diagnostics, turn off the computer, insert a diagnostics diskette into
drive A, and then turn on the computer.
Starting the diagnostics causes the Dell logo to appear on the screen, followed
by a message indicating that the diagnostics is loading. Before the diagnostics
loads, a program tests the portion of main memory (RAM) required for loading
the diagnostics. If a main memory error is detected, a message appears on the
screen telling you which DIMM has failed.
Summary of Contents for Dimension XPS R Series
Page 1: ...ZZZ GHOO FRP HOO LPHQVLRQ 36 5 6 VWHPV 6 59 0 18 ...
Page 7: ...ix ...
Page 16: ...1 8 Dell Dimension XPS Rxxx Systems Service Manual LJXUH 3RZHU DEOHV P1 P7 P2 P3 P6 P5 P4 ...
Page 30: ...1 22 Dell Dimension XPS Rxxx Systems Service Manual ...
Page 38: ...2 8 Dell Dimension XPS Rxxx Systems Service Manual ...
Page 44: ...3 6 Dell Dimension XPS Rxxx Systems Service Manual ...