Figure 4. Status LED indicators
Table 10. Status LED indicators and descriptions
Icon
Description
Condition
Corrective action
Drive indicator The indicator turns solid
amber if there is a drive error.
Check the System Event Log to determine if the drive has an
error.
If the problem persists, see the
Temperature
indicator
The indicator turns solid
amber if the system
experiences a thermal error
(for example, the ambient
temperature is out of range or
there is a fan failure).
Ensure that none of the following conditions exist:
●
A cooling fan has been removed or has failed.
●
Appliance cover, air shroud, memory module blank, or back
filler bracket is removed.
●
Ambient temperature is too high.
●
External airflow is obstructed.
If the problem persists, see the
Electrical
indicator
The indicator turns solid
amber if the system
experiences an electrical error
(for example, voltage out
of range, or a failed power
supply unit (PSU) or voltage
regulator).
Check the System Event Log or appliance messages for the
specific issue. If it is due to a problem with the PSU, check the
LED on the PSU. Reseat the PSU.
If the problem persists, see the
Memory
indicator
The indicator turns solid
amber if a memory error
occurs.
See the
section.
PCIe indicator The indicator turns solid
amber if a PCIe card
experiences an error.
See the
section.
System health and system ID indicator codes
Figure 5. System health and system ID indicators
Table 11. System health and system ID indicator codes
System health and system ID indicator code
Condition
Solid blue
Indicates that the system is turned on, system is healthy, and
system ID mode is not active. Press the system health and
system ID button to switch to system ID mode.
12