VLAN Stacking
With the virtual local area network (VLAN)-stacking feature (also called stackable VLANs and QinQ), you can
“stack” VLANs into one tunnel and switch them through the network transparently.
For more information about basic VLAN commands, see the
Virtual LAN (VLAN) Commands
section in the
chapter.
Important Points to Remember
• If you do not enable the spanning tree protocol (STP) across the stackable VLAN network, STP bridge
protocol data units (BPDUs) from the customer’s networks are tunneled across the stackable VLAN
network.
• If you do enable STP across the stackable VLAN network, STP BPDUs from the customer’s networks are
consumed and not tunneled across the stackable VLAN network unless you enable protocol tunneling.
NOTE:
For more information about protocol tunneling on the E-Series, see
.
• Layer 3 protocols are not supported on a stackable VLAN network.
• Assigning an IP address to a stackable VLAN is supported when all the members are only stackable VLAN
trunk ports. IP addresses on a stackable VLAN-enabled VLAN are not supported if the VLAN contains
stackable VLAN access ports. This facility is provided for the simple network management protocol
(SNMP) management over a stackable VLAN-enabled VLAN containing only stackable VLAN trunk
interfaces. Layer 3 routing protocols on such a VLAN are not supported.
• Dell Networking recommends that you do not use the same MAC address, on different customer VLANs,
on the same stackable VLAN.
• Interfaces configured using stackable VLAN access or stackable VLAN trunk commands do not switch
traffic for the default VLAN. These interfaces are switch traffic only when they are added to a non-
default VLAN.
• Starting with the Dell Networking OS version 7.8.1 for C-Series and S-Series (Dell Networking OS version
7.7.1 for E-Series, 8.2.1.0 for E-Series ExaScale), a vlan-stack trunk port is also allowed to be configured
as a tagged port and as an untagged port for single-tagged VLANs. When the vlan-stack trunk port is
also a member of an untagged vlan, the port must be in Hybrid mode. See
• VLAN stacking is not supported on Port Extender (PE) ports and on LAGs with port extender ports.
• VLAN stacking interface commands are blocked (hidden) on PE ports.
• VLAN stacking interface commands will fail on the VP-LAG (LAG with PE ports).
Topics:
•
•
•
•
65
VLAN Stacking
2278
Summary of Contents for C9000 series
Page 1: ...Dell Networking Command Line Reference Guide for the C9000 Series Version 9 10 0 0 ...
Page 394: ...deny 14551 666 Dell Access Control Lists ACL 394 ...
Page 877: ...algorithm FIPS Cryptography 877 ...
Page 1297: ...Total 5 0 Total 5 active route s using 952 bytes IPv6 Basics 1297 ...