![Dell C9000 series Reference Manual Download Page 1031](http://html.mh-extra.com/html/dell/c9000-series/c9000-series_reference-manual_230451031.webp)
The following example shows the
show port-channel-flow outgoing-port-
channel
number
incoming-interface
interface
source-mac
address
destination-mac
address
• Load-balance is configured for MAC
• Load-balance is configured for IP 4-tuple/2-tuple
• A non-IP payload is going out of Layer 2 LAG interface that is a member of VLAN
with an IP address
Example
Dell#show port-channel-flow port-channel 1 incoming-interface te
2/0
source-mac 00:00:50:00:00:00 destination-mac 00:00:a0:00:00:00
Egress Port for port-channel 1, for the given flow, is Te 2/1
Example: peGigE
Dell#show port-channel-flow port-channel 111 incoming-interface
pegigE 111/0/33
src-mac 00:01:0b:00:00:00 dest-mac 00:01:0b:00:03:00 vlan 111
ether-type ff:ff
Egress Port information for port-channel 111, for the given
flow,is
PeGi 111/0/38.
HiGig Port Channel Commands
High-Gigabit Ethernet (HiGig) port channels are used to transmit data between internal backplane ports on
line-card (leaf) and switch fabric module (SFM - spine) network processing units (NPUs). You can configure an
SNMP trap to be generated when traffic distribution in a HiGig port channel is uneven.
NOTE:
HiGig port channels on the backplane are also referred to as
HiGig link bundles
.
The backplane port channels operate as HiGig link bundles to transmit data traffic between line-card and SFM
NPUs. There are 10 line-cards and 2 SFM NPUs. The 6 SFM (spine) NPUs comprise the switch fabric module.
Each line-card has one NPU numbered 0. SFM NPUs are numbered 0 to 1.
Line-card and SFM NPUs use HiGig port channels to transmit data.
• An SFM NPU uses 10 HiGig port channels, one port channel to transmit data to each line-card NPU.
Each HiGig port channel in an SFM NPU consists of three HiGig links.
• A line-card NPU supports 24 front-end I/O ports and six backplane HiGig ports. The six backplane links
are members of two HiGig port channel that connects the line-card NPU to each SFM NPU. Three HiGig
links in the port channel are used to connect to each SFM NPU.
Interfaces
1031
Summary of Contents for C9000 series
Page 1: ...Dell Networking Command Line Reference Guide for the C9000 Series Version 9 10 0 0 ...
Page 394: ...deny 14551 666 Dell Access Control Lists ACL 394 ...
Page 877: ...algorithm FIPS Cryptography 877 ...
Page 1297: ...Total 5 0 Total 5 active route s using 952 bytes IPv6 Basics 1297 ...