background image

 

SCG2013  |  Brocade VDX 6740 Switch Configuration Guide for Dell SC Series SANs 

Table of contents 

Revisions ............................................................................................................................................................................................. 2

 

1

 

Introduction ................................................................................................................................................................................ 4

 

1.1

 

Document conventions ................................................................................................................................................. 4

 

1.2

 

Audience ........................................................................................................................................................................... 4

 

1.3

 

Switch details ................................................................................................................................................................... 4

 

1.4

 

Cabling diagram .............................................................................................................................................................. 5

 

2

 

Dell recommended switch configuration ............................................................................................................................. 6

 

2.1

 

Hardware configuration ................................................................................................................................................. 6

 

2.2

 

Delete startup configuration ......................................................................................................................................... 6

 

2.3

 

Configure Global LLDP settings to disable DCB ....................................................................................................... 7

 

2.4

 

Disable Ethernet Fabric on edge ports ........................................................................................................................ 7

 

2.5

 

Enable Jumbo MTU ........................................................................................................................................................ 7

 

2.6

 

Enable Switchport ........................................................................................................................................................... 7

 

2.7

 

Enable link level flow control (802.3x) ........................................................................................................................ 7

 

2.8

 

Configure Spanning tree on edge ports ..................................................................................................................... 8

 

2.9

 

Disable LLDP iSCSI priority on Switch Ports ............................................................................................................... 8

 

2.10

 

Save configuration .......................................................................................................................................................... 8

 

2.11

 

Configure additional switch .......................................................................................................................................... 8

 

3

 

Performance tuning .................................................................................................................................................................. 9

 

4

 

Configuring VCS ID and Rbridge-ID (optional) .................................................................................................................. 10

 

A

 

Additional resources ................................................................................................................................................................. 11

 

 

Summary of Contents for Brocade VDX 6740

Page 1: ...A Dell Deployment and Configuration Guide Brocade VDX 6740 Switch Configuration Guide for Dell SC Series SANs Dell Storage Engineering November 2015 ...

Page 2: ...OVIDED AS IS WITHOUT EXPRESS OR IMPLIED WARRANTIES OF ANY KIND 2015 Dell Inc All rights reserved Dell the DELL logo and the DELL badge are trademarks of Dell Inc Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products Dell disclaims any proprietary interest in the marks and names of others Date Description Novembe...

Page 3: ...on 6 2 2 Delete startup configuration 6 2 3 Configure Global LLDP settings to disable DCB 7 2 4 Disable Ethernet Fabric on edge ports 7 2 5 Enable Jumbo MTU 7 2 6 Enable Switchport 7 2 7 Enable link level flow control 802 3x 7 2 8 Configure Spanning tree on edge ports 8 2 9 Disable LLDP iSCSI priority on Switch Ports 8 2 10 Save configuration 8 2 11 Configure additional switch 8 3 Performance tuni...

Page 4: ...ask 1 2 Audience This switch configuration guide describes a verified configuration following Dell best practices for an SC Series iSCSI SAN and is intended for storage or network administrators and deployment personnel 1 3 Switch details Table 2 provides an overview of the switch configuration Table 2 Switch specifications Brocade VDX 6740 Switch vendor Brocade Switch model VDX 6740 Switch firmwa...

Page 5: ...DX 6740 Switch Configuration Guide for Dell SC Series SANs 1 4 Cabling diagram The cabling diagram shown below represents the Dell recommend method for deploying your servers and SC Series arrays Figure 1 Cabling diagram ...

Page 6: ...etween switch 1 and switch 2 as shown in Figure 1 This will be used as your Brocade LAG link Note The below configuration steps assumes that the switch is configured with a unique Rbridge id and VCS id Refer to section 4 on how to change the Rbridge id and VCS id of the switch 2 2 Delete startup configuration Note This example assumes a switch at its default configuration settings The copy default...

Page 7: ...net 1 0 1 48 sw0 conf if te 1 0 1 48 no fabric isl enable sw0 conf if te 1 0 1 48 no fabric trunk enable sw0 conf if te 1 0 1 48 exit 2 5 Enable Jumbo MTU sw0 config interface TenGigabitEthernet 1 0 1 48 sw0 conf if te 1 0 1 48 mtu 9216 sw0 conf if te 1 0 1 48 exit 2 6 Enable Switchport sw0 config interface TenGigabitEthernet 1 0 1 48 sw0 conf if te 1 0 1 48 switchport sw0 conf if te 1 0 1 48 swit...

Page 8: ...ort sw0 conf if te 1 0 1 48 exit 2 9 Disable LLDP iSCSI priority on Switch Ports sw0 config interface TenGigabitEthernet 1 0 1 48 sw0 conf if te 1 0 1 48 no lldp disable sw0 conf if te 1 0 1 48 no cee sw0 conf if te 1 0 1 48 no lldp iscsi priority sw0 conf if te 1 0 1 48 exit sw0 config exit 2 10 Save configuration switch copy running config startup config 2 11 Configure additional switch Repeat t...

Page 9: ...nce can be optimized by increasing TX and RX buffers per port per queue Optimal performance can be achieved when using a setting of 2MB for receive queue and 2MB for transmit queue per port The following instructions show how to configure the receive and transmit buffers sw0 configure Entering configuration mode terminal sw0 config rbridge id 1 sw0 config rbridge id 1 qos tx queue limit 2000 sw0 c...

Page 10: ... change is not required for the mode sw0 show vcs Config Mode Local Only VCS Mode Fabric Cluster VCS ID 1 Total Number of Nodes 1 Rbridge Id WWN Management IP VCS Status Fabric Status HostName 2 10 00 50 EB 1A 2D F2 64 77 77 77 77 Online Online sw0 sw0 vcs vcsid 2 This operation will change the configuration to default and reboot the switch Do you want to continue y n y Note The switch will reboot...

Page 11: ...out Dell products and your installations Referenced or recommended Dell publications Dell EqualLogic Configuration Guide http en community dell com techcenter storage w wiki equallogic configuration guide aspx Dell Storage Compatibility Matrix http en community dell com techcenter storage w wiki 5069 dell storage compatibility matrix For SC Series best practices white papers reference architecture...

Reviews: