IDSDM or vFlash module
The VxRail P580N system features an Internal Dual SD module (IDSDM) or vFlash module. The
IDSDM or vFlash module is combined into a single card module, and includes both vFlash and
IDSDM. The IDSDM or vFlash module is located in a slot on the back of the system. The module
supports three microSD cards; two cards for IDSDM and one card for vFlash. The following
capacities are supported:
l
IDSDM: 64 GB
Note:
There are two dip switches on the IDSDM or vFlash module for write-protection.
Note:
One IDSDM card slot is dedicated for redundancy.
Note:
Use Dell branded microSD cards associated with the IDSDM or vFlash configured
systems.
Video specifications
VxRail P580N appliances support the integrated Matrox G200eW3 graphics controller with 16 MB
of video frame buffer.
The following table describes the supported video resolution options.
Video resolution options
Table 20 Supported video resolution options
Resolution
Refresh rate (Hz)
Color depth (bits)
1024 x 768
60
8, 16, 32
1280 x 800
60
8, 16, 32
1280 x 1024
60
8, 16, 32
1360 x 768
60
8, 16, 32
1440 x 900
60
8, 16, 32
1600 x 900
60
8, 16, 32
1600 x 1200
60
8, 16, 32
1680 x 1050
60
8, 16, 32
1920 x 1080
60
8, 16, 32
1920 x 1200
60
8, 16, 32
Note:
1920 x 1080 and 1920 x 1200 resolutions are supported only in reduced blanking mode.
Environmental specifications
When the system is in continuous operation (for altitude less than 950 m or 3117 ft), the
temperature specification ranges 10 °C–35°C (50–95°F) with no direct sunlight on the
equipment. When the system is not in operation, the temperature specification is –40 °C–65°C (–
40–149°F). For more information about fresh air, see the Expanded Operating Temperature
section. The Maximum temperature gradient for both operation and nonoperational systems is
Technical specifications
Dell EMC VxRail Appliances on Dell PowerEdge Servers VxRail P580N Owner's Manual