Dell EMC SD-WAN Edge 3000 Series Installation Guide
August 2019
Page 1: ...Dell EMC SD WAN Edge 3000 Series Installation Guide August 2019 ...
Page 2: ...amage to hardware or loss of data and tells you how to avoid the problem WARNING A WARNING indicates a potential for property damage personal injury or death 2019 Dell Inc or its subsidiaries All rights reserved Dell EMC and other trademarks are trademarks of Dell Inc or its subsidiaries Other trademarks may be trademarks of their respective owners 2019 08 Rev A00 ...
Page 3: ...3 Power 13 Storing components 13 4 Edge 3000 Series installation 14 Unpack 14 Ground lug 14 Rack or cabinet hardware installation 15 Two post installation 16 1U front rack installation 16 Four post installation 17 Optics installation 18 Optics removal 18 Platform power up 18 5 Platform setup 20 6 Power supplies 22 Components 22 AC power supply installation 22 AC power supply replacement 23 7 Fans ...
Page 4: ...sis physical design 31 IEEE standards 32 Agency compliance 32 USA Federal Communications Commission statement 32 European Union EMC directive conformance statement 33 Japan VCCI compliance for class A equipment 33 Korean certification of compliance 34 Safety standards and compliance agency certifications 34 Product recycling and disposal 35 11 Dell EMC support 36 4 Contents ...
Page 5: ...e optical transceiver ports Avoid exposure to laser radiation Do not stare into open apertures NOTE Read this guide before unpacking the platform For unpacking instructions see Unpack Regulatory Marketing model Edge 3400 and 3800 platform is represented by the regulatory model E25W and the regulatory type E25W001 Topics Related documents Information symbols Related documents For more information a...
Page 6: ...The Warning icon signals information about hardware handling that could result in injury NOTE The ESD Warning icon requires that you take electrostatic precautions when handling the device 6 About this guide ...
Page 7: ... and 3800 is a Dell EMC purpose built platform complete with VeloCloud software The high performance platform hosts VMware SD WAN software and is meant for the service provider edge or enterprise branch The platform includes two 10 100 1000Base T management ports one for the central processing unit CPU and one for the baseboard management controller BMC It also includes two Type A USB ports that s...
Page 8: ...side of the platform VMware SD WAN software pre loaded Physical dimensions 17 1 in x 15 in x 1 72 in W x D x H 43 4 cm x 38 1 cm x 4 37 cm W x D x H LEDs The Edge 3000 Series platform includes LED displays on the I O side of the platform 1 Master LED 2 System LED 3 Locator LED 4 Power LED 5 Fan LED 6 Temperature LED 7 BMC and CPU console and management port LEDs 8 rNDC system and temperature LEDs ...
Page 9: ...emperature is over the limit rNDC System LED Off system off or in standby Solid green Normal operation Flashing green Booting Solid yellow amber Critical system error Flashing yellow Noncritical system error rNDC Temperature LED Off system off or in standby Solid green temperature is normal Solid yellow temperature is at the limit Flashing yellow temperature is over the limit 10 GbE SFP port LEDs ...
Page 10: ...00 Series installation The following is a list of components need to install the Edge 3000 Series platform Dell EMC SD WAN Edge 3400 or 3800 platform AC country and regional specific cables Two post rail kit mounting brackets for rack installation included Screws for rack installation 1 and 2 Phillips screwdrivers not included M2 Philips drive flat head screwdriver not included Ground cable screws...
Page 11: ...1 SVC tag 2 MAC address 3 PPID 4 Express service code Edge 3000 Series 11 ...
Page 12: ...irect sunlight Away from sources of severe electromagnetic noise Inside the restricted access area that is positioned in a rack or cabinet or on a desktop with adequate space in the front back and sides for proper ventilation and access Install the platform in Information Technology Rooms in accordance with Article 645 of the National Electrical Code and NFPA 75 For more information about platform...
Page 13: ... multiple power cables Before servicing ensure that all power cables are disconnected CAUTION Use the AC power supply cord as the main disconnect device Ensure that the socket outlet is located and installed near the equipment and is easily accessible Processor power button The processor power button is on the I O side of the platform To turn on the processor hold the button down for one second To...
Page 14: ...ion Dell EMC SD WAN Edge 3000 Series Quick Start Guide Safety and Regulatory Information Warranty and Support Information 1 Place the container on a clean flat surface and cut all straps securing the container 2 Open the container or remove the container top 3 Carefully remove the platform from the container and place it on a secure and clean surface 4 Remove all packing material 5 Inspect the pro...
Page 15: ...o post rails as a shelf or a workplace Rack mount safety considerations Rack loading Overloading or uneven loading of racks may result in shelf or rack failure possibly damaging the equipment and causing personal injury Stabilize racks in a permanent location before loading begins Mount the components starting at the bottom of the rack and then work to the top Do not exceed your load rating of the...
Page 16: ...es platform Line up the half holes on the rail with the mounting heads on the platform and attach the rail to the platform Slide the rail back until it locks into place 2 Repeat on the other side of the platform 3 Attach the outer platform rails to the two post rack rails using two user supplied screws on each side 4 After you install both rails line up the platform rails with the installed rack r...
Page 17: ...stallation supply eight rack mounting screws 1 Separate each rail assembly by sliding the inside rail out of the outside rail 2 Attach the inner platform rails to the Edge 3000 Series platform Line up the half holes on the rail with the mounting heads on the platform and attach the rail to the platform Slide the rail back until it locks into place 3 Repeat on the other side of the platform 4 Attac...
Page 18: ...sliding the optic from the port When removing optics with direct attach cables DACs from the port pull the release tab firmly and steadily Before pulling the release tab you may need to gently push the optic into the port to ensure that it is seated properly Do not jerk or tug repeatedly on the tab Platform power up Supply power to the Edge 3000 Series after it is mounted in a rack or cabinet Dell...
Page 19: ...Power up sequence When the platform powers up the fans immediately come on at high speed The fan speed slows as the platform continues to boot Edge 3000 Series installation 19 ...
Page 20: ...n the workplace The numbers one through four in the following figure correspond to the setup procedure 1 Connect the power adapter to the AC power outlet These power modules are 1 1 redundant power supplies NOTE Connect the device to a properly wired earth ground AC power outlet 2 Connect one of the default WAN ports GE3 6 or SFP1 4 to an available Internet connection SFP modules are not included ...
Page 21: ...After following these instructions if you are still unable to activate the Edge contact your Dell EMC sales representative Platform setup 21 ...
Page 22: ...y that the remote power source complies with the platform input power specifications NOTE If you use a single PSU install a blank plate in the other PSU slot Use power supply 2 PSU2 as the blank plate slot You do not need tools to install the blank plate NOTE ESD damage can occur if components are mishandled Always wear an ESD preventive wrist or heel ground strap when handling the platform and co...
Page 23: ...and the power source AC power supply replacement CAUTION Disconnect the power cable before removing the power supplies Also disconnect all power cable before servicing NOTE The PSU slides into the slot smoothly Do not force a PSU into a slot as this action may damage the PSU or the platform NOTE If a PSU fails you must replace the entire unit There are no field serviceable components in the PSU To...
Page 24: ...n temperature and or particulate matter in the air might affect performance for example new equipment installation CAUTION Check the fans at six month intervals replace them as necessary Regularly monitor the speeds of the fans to accurately determine replacement intervals Topics Components Fan module installation Components 16 core five fans 8 core four fans 1 Fans Fan LEDs Solid green Fan functi...
Page 25: ...lacement see https www dell com support CAUTION Complete the following steps within one minute or the platform temperature could rise above safe thresholds and the platform could shut down 1 Slide the fan module out of the bay 2 Slide the replacement module into the bay Fans 25 ...
Page 26: ...longer than 6m when disconnected from the panel or server your platform may not boot NOTE Before starting this procedure ensure that your personal computer has a 9 pin serial port and that you have installed a terminal emulation program on the personal computer NOTE If your personal computer serial port cannot accept a female DB 9 connector use a DB 9 male to male adapter 1 Install the provided RJ...
Page 27: ...ce 1 Power on the personal computer 2 Connect the USB A end of cable into an available USB port on the personal computer 3 Connect the MicroUSB B end of cable into the microUSB B console port on the platform 4 Power on the platform 5 Install the necessary USB device drivers To download Dell EMC drivers see https www dell com support If your computer requires non Dell EMC drivers contact Dell EMC T...
Page 28: ...ies Reset settings Overview The Overview page provides the status of the routed interfaces WAN and switched interfaces LAN connections The top half of the screen displays a diagram of the device If connections are active green indicator lights display on the hardware diagram On the Overview page next to the device image are two buttons Overview and Details To display WAN and LAN connection status ...
Page 29: ... and change the connection properties For example you can specify a static IP address for the interface or select a PPPoE for the connection However Dell EMC recommends entering static and PPPoE values using Device Settings override on the Orchestrator When you finish changing the properties click the Save Changes button To return to the previous screen click the Return button User interface 29 ...
Page 30: ...the platform When the service light illuminates again the device has completed the reboot process Reset Configuration Returns the platform to an unactivated state Cloud services are turned off the platform is no longer associated with a cloud managed configuration and the initial default configuration reapplies Hard Reset Deactivates the platform restores default configuration and restores the ori...
Page 31: ...ht 1 72 inches 43 7 cm Width 17 1 inches 43 4 cm Depth 15 inches 38 1 cm PSU fan tray handle 1 57 inches 40 mm Chassis weight with factory installed components including one rNDC carrier card one rNDC card and one blank panel 16 core 16 50 lbs 7 48 kg 2 PSUs and 5 fans 8 core 16 60 lbs 7 53 kg 2 PSUs and 4 fans Rack clearance required Front 5 inches 12 7 cm Back 5 inches 12 7 cm Table 4 Environmen...
Page 32: ...igital device pursuant to Part 15 of the FCC rules These limits are designated to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy If it is not installed and used in accordance to the instructions it may cause harmful interference to radio communications Operati...
Page 33: ...il Directive 2004 108 EC on the approximation of the laws of the Member States relating to electromagnetic compatibility Dell EMC cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non recommended modification of this product including the fitting of non Dell EMC option cards This product has been tested and found to comply with the limits for Clas...
Page 34: ... Figure 5 Korean package label Radio compliance certificate Korea Korean warning statement is only required for devices contain 2400 2483 and or 5725 5825 MHz radios 해당 무선설비는 운용 중 전파혼신 가능성이 있음 Korean radio compliance certificate Safety standards and compliance agency certifications CUS UL 60950 1 2nd Edition CSA 60950 1 03 2nd Edition EN 60950 1 2nd Edition IEC 62368 1 EN 60825 1 1st Edition EN 60...
Page 35: ... the product is not to be thrown away but rather reclaimed upon end of life per this Directive Figure 6 The European WEEE symbol In accordance with the European WEEE Directive electrical and electronic equipment EEE is to be collected separately and to be reused recycled or recovered at end of life Users of EEE with the WEEE marking per Annex IV of the WEEE Directive as shown above must not dispos...
Page 36: ...lect your country from the drop down menu To obtain product specific information enter the 7 character service tag or the 11 digit express service code of your platform and click submit To view the platform service tag or express service code pull out the luggage tag on the upper right side of the platform or retrieve it remotely using the ipmitool H bmc ip address I lanplus U user name P password...