Table 73. Supported rear video resolution options
Resolution
Refresh rate (Hz)
Color depth (bits)
1024 x 768
60
8, 16, 32
1280 x 800
60
8, 16, 32
1280 x 1024
60
8, 16, 32
1360 x 768
60
8, 16, 32
1440 x 900
60
8, 16, 32
1600 x 900
60
8, 16, 32
1600 x 1200
60
8, 16, 32
1680 x 1050
60
8, 16, 32
1920 x 1080
60
8, 16, 32
1920 x 1200
60
8, 16, 32
Environmental specifications
NOTE:
For additional information about environmental certifications, refer to the
Product Environmental Datasheet
located with the Manuals & Documents on
.
Table 74. Operational climatic range category A2
Temperature
Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<=
2953 ft)
10–35°C (50–95°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all
times)
8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum
dew point
Operational altitude de-rating
Maximum temperature is reduced by 1°C/300 m (33.8°F/984 Ft) above 900 m
(2953 Ft)
Table 75. Operational climatic range category A3
Temperature
Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<=
2953 ft)
5–40°C (41–104°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all
times)
8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum
dew point
Operational altitude de-rating
Maximum temperature is reduced by 1°C/175 m (33.8°F/574 Ft) above 900 m
(2953 Ft)
Table 76. Operational climatic range category A4
Temperature
Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<=
2953 ft)
5–45°C (41–113°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all
times)
8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum
dew point
192