Installing the left control panel
Prerequisite
Follow the safety guidelines listed in
Steps
1
Route the control panel cable through the side wall of the system.
2
Align the left control panel assembly with the control panel slot on the system and place the assembly in the slot on the system.
3
Connect the control panel cable to the system board connector.
4
Using Phillips #1 screwdriver, install the screws that secure the cable cover to the system.
Figure 101. Installing the cable cover
Next steps
1
2
Install the internal PERC riser.
3
Follow the procedure listed in
After working inside your system
.
Removing the right control panel
Prerequisites
1
Follow the safety guidelines listed in
2
Follow the procedure listed in
Before working inside your system
.
3
Remove the internal PERC riser.
Steps
1
Lift the cable latch and disconnect the control panel cable from the connector on the system board.
NOTE:
Ensure that you note the routing of the cables as you remove them from the system board. You must route the
cables properly when you replace them to prevent the cables from being pinched or crimped.
2
Using a Phillips #1 screwdriver, remove the screws that secure the cable cover to the system.
138