Parameters
Table 15. List temperature sensors
Parameter
Description
-a
Specifies the adapter used for the command. This is either SAS WWID or
AdapterIndex.
-enc
Specifies the enclosure used for the command. This is either WWN or EnclIndex.
-h
Provides more information about the command, description, and usage.
-outputformat
You can specify the following output formats: XML or JSON.
Command examples
•
list temp sensors -a = 1 -enc = 500a123456789012
•
list temp sensors -a = 1 -enc = 0
•
list temp sensors -enc = 500a123456789012 -outputformat = xml
List voltage sensors
Description
This command lists the voltage sensors accessible from the specified enclosure.
Command syntax
shmcli (list voltage sensors | listvoltagesensors | lvs) (-a=<(SAS WWID | AdapterIndex)> -
enc=<(WWN | EnclIndex)> [-outputformat=<SupportedOutputFormats>] | -enc=<WWN> [-
outputformat=<SupportedOutputFormats>] | [-h])
Parameters
Table 16. List voltage sensors
Parameter
Description
-a
Specify the adapter used for the command. This can be either SAS
WWID or AdapterIndex.
-enc
Specify the enclosure used for the command. This is either WWN
or EnclIndex.
-h
Provides more information about the command, description, and
usage.
-outputformat
You can specify the following output formats: XML or JSON.
30
CLI reference