Figure 27 Power supply LEDs
Table 35 SAS link LEDs
LED
Color
State
Description
PSU Fail
Amber
Solid
There is a fault in the power supply
PSU Identify
Blue
Solid
The power supply received an
identify command
AC OK
Green
Solid
AC power input is within regulation
DC OK
Green
Solid
DC power output is within regulation
Fan modules
The Pikes Peak DAE has three hot-swappable managed system fans at the rear in a
redundant 2-plus-1 configuration. Logic in the DAE will gracefully shut down the DAE
if the heat becomes too high after a fan failure. A failed fan must be left in place until
the fan replacement service call. Each fan has an amber fault LED. The fans are
labeled A, B, and C from right to left.