Table 27 7150S switch port connections used on the top 10 GbE switch (
hare
)
Figure label Ports
Connection description
1
1–8
The 10 GbE uplink data ports. These ports provide the
connection to the customer's 10 GbE infrastructure. SR Optic.
See note.
2, 3
9–20
The 10 GbE node data ports. Only ports 9–16 are used in U-
and D-Series. These ports are connected to the left (P02) 10
GbE interface on each node. SR Optic.
4, 5
21–24
Unused.
4
45–48
The 10 GbE LAG ports. These ports are connected to the LAG
ports on the bottom 10 GbE switch (
rabbit
). SR Optic.
5
49–52
Unused.
6
<...>
The 1 GbE management port. This port is connected to port
50 of the management switch (
turtle
). RJ-45.
7
Serial console The console port is used to manage the switch through a
serial connection. The Ethernet management port is
connected to the 1 GbE management switch.
Table 28 7150S switch port connections used on the bottom 10 GbE switch (
rabbit
)
Figure label Ports
Connection description
1
1–8
The 10 GbE uplink data ports. These ports provide the
connection to the customer's 10 GbE infrastructure. SR Optic.
See note.
2, 3
9–20
The 10 GbE node data ports. Only ports 9–16 are used in U-
and D-Series. These ports are connected to the right (P01) 10
GbE interface on each node. SR Optic.
4, 5
21–24
The 10 GbE LAG ports. These ports are connected to the LAG
ports on the top 10 GbE switch (
hare
). SR Optic.
6
<...>
The 1 GbE management port. This port is connected to port
49 of the management switch (
turtle
). RJ-45.
7
Serial console The console port is used to manage the switch through a
serial connection. The Ethernet management port is
connected to the 1 GbE management switch.
Note
10 GbE switches ship with one SFP - RJ-45 copper SFP installed in port 1. Fibre SFPs
can be ordered through Dell EMC. An ECS appliance that is shipped in a Dell EMC rack
has all SFPs installed, but not installed for a customer rack installation. In either case,
the switch may require additional SFPs to be installed or reconfigured in ports 1–8
based on customer uplink configuration.
Switches
Public switch: Arista 7150S-24
41
Summary of Contents for ECS D Series
Page 1: ...Dell EMC Elastic Cloud Storage ECS D and U Series Hardware Guide 302 003 477 09 ...
Page 8: ...TABLES 8 D and U Series Hardware Guide ...
Page 25: ...CHAPTER 2 Servers l ECS Appliance servers 26 l Rack and node host names 30 Servers 25 ...
Page 32: ...Servers 32 D and U Series Hardware Guide ...
Page 33: ...CHAPTER 3 Switches l ECS Appliance switches 34 Switches 33 ...
Page 44: ...Switches 44 D and U Series Hardware Guide ...
Page 70: ...Third Party Rack Requirements 70 D and U Series Hardware Guide ...
Page 88: ...Power Cabling 88 D and U Series Hardware Guide ...
Page 89: ...CHAPTER 7 SAS Cabling l U Series SAS cabling 90 l D Series SAS cabling 93 SAS Cabling 89 ...
Page 99: ...Figure 61 U Series and D Series network cabling Network Cabling Network cabling 99 ...