Figure 41. Installing the butterfly module
Next steps
1
2
Follow the procedure listed in
After working inside your system
Processor and heat sink
Removing the processor and heat sink
Prerequisites
WARNING:
The heat sink may be hot to touch for some time after the system is powered down. Allow the heat sink to cool
before removing it.
1
Follow the safety guidelines listed in
2
Follow the procedure listed in
Before working inside your system
.
3
Remove the following:
a
b
Steps
1
Using a Torx #T30 screwdriver, loosen the screws on the heat sink in the order below:
a Loosen the first screw three turns.
b Loosen the second screw completely.
c Return to the first screw and loosen it completely.
Installing and removing system components
65