Note

1RU = 1 Retention Unit , size equal to active tier

1. If you already have more than 1 RU, you get to keep it when you upgrade to DD OS

5.5.1. But there is a caveat: you cannot use encryption or any new feature that we
add after 5.5.1.

2. You cannot configure more than 1RU per storage tier when using DD OS 5.5.1 and

later.

Installing or adding ES30 and FS15 shelves

Refer to the table and related information in 

Shelf cabling rules and guidelines

 on page

21 for shelf configuration restrictions.

Ports

Depending on the model, a Data Domain system has one to four dual- or quad-port
SAS HBA cards or SAS I/O modules installed. The ES30 shelf has two controllers (B
located above A). Each controller has two ports, a host and an expansion port.

See 

Data Domain-Specific Installation

 on page 111 for SAS HBA card, SAS I/O

module, and port locations.

Cabling shelves

Note

l

Before cabling the shelves, physically install all shelves in the racks. Refer to the
rail kit installation instructions included with the ES30 shelf for rack mounting.

l

The documentation refers to two SAS HBAs. If only one HBA is allowed in a
system, then use another port as defined later for that specific system.

l

On an HA system, add cables from the second node to open ports at the end of
the sets. The ports on the second node must connect to the same sets as the
corresponding ports on the first node.

Ports on the Data Domain system’s SAS HBA cards connect directly to a shelf
controller’s host port. For redundancy, you need to create dual paths by using a port
on one SAS HBA card to connect to one shelf controller in each shelf set, and a port
on another SAS HBA card to connect to another shelf controller in the same shelf set.
With dual paths, if one SAS HBA card fails, the shelf is still operational. However, in
the unlikely event any single shelf becomes completely disconnected from power or
SAS cables and becomes disconnected from a previously operational shelf, the file
system goes down and the shelf is not operational. This is considered a double failure.

There are two kinds of configurations: one shelf in a set or multiple shelves in a set.

Installing the Shelves

28

Data Domain ES30 Expansion Shelf and FS15 SSD Shelf

  

Hardware Guide

Summary of Contents for Data Domain ES30 Expansion Shelf

Page 1: ...Dell EMC Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide 302 002 104 REV 04 ...

Page 2: ...UBLICATION AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE USE COPYING AND DISTRIBUTION OF ANY DELL SOFTWARE DESCRIBED IN THIS PUBLICATION REQUIRES AN APPLICABLE SOFTWARE LICENSE Dell EMC and other trademarks are trademarks of Dell Inc or its subsidiaries Other trademarks may be the property of their respective owners Published in the USA Dell E...

Page 3: ...00 and DD7200 cabling 44 DD6300 DD6800 and DD9300 cabling 61 DD9500 and DD9800 cabling 66 Connecting power 73 Attaching the power supplies 73 Types of cabinets and power connections 74 Single phase power connections for 40U P current racks 75 Single phase power connections for 40U C older racks 83 3 Phase power connections for 40U P current racks 87 3 Phase power connections for 40U C older racks ...

Page 4: ...wer on sequence 121 Connect power to shelves 121 Verifying shelf installation 123 Add enclosure disks to the volume 126 Hardware Specifications 129 ES30 and FS15 hardware specifications 130 Chapter 4 Appendix A CONTENTS 4 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 5: ...ta Domain Operating System release being used in your environment l Data Domain Operating System Release Notes l Data Domain Operating System Initial Configuration Guide l Data Domain Operating System Administration Guide l Data Domain Operating System Command Reference Guide l The Data Domain system installation and setup guides for each of the supported platforms for example DD4500 l For Data Do...

Page 6: ... error message or script l Pathnames filenames prompts and syntax l Commands and options Monospace italic Use for variables Monospace bold Use for user input Square brackets enclose optional values Vertical bar indicates alternate selections the bar means or Braces enclose content that the user must specify such as x or y or z Ellipses indicate nonessential information omitted from the example Tec...

Page 7: ...topics and cabling diagrams as they relate to supporting the FS15 shelf and the DD6300 DD6800 and DD9300 and DD9800 systems 02 March 2016 302 000 104 Rev 02 5 7 1 Support for DD OS High Availability HA 01 July 2015 302 000 104 Rev 01 5 7 l Support 4TB drives on DD4500 DD7200 and DD9500 systems l End of support of DD660 DD690 and DD880 systems This document was first published in July 2011 with a d...

Page 8: ...Revision history 8 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 9: ...assis used in all ES30 products it can only be used with DD6300 DD6800 and DD9300 and DD9500 and DD9800 systems configured with DD OS 6 0 and later Note l Data Domain systems that support the ES30 shelves must be running DD OS 5 1 and later l For instructions on replacing one of the field replaceable components see the appropriate ES30 Field Replaceable Unit FRU documentation on the Data Domain Su...

Page 10: ...area for airflow Whether in an open or enclosed rack use filler panels to prevent hot air recirculation The rack design and installation should take into consideration the maximum ambient operating temperature of the equipment which is 35 C Power Grounding Two single phase AC power outlets with an earth ground conductor safety ground A safe electrical earth connection must be provided to each powe...

Page 11: ...o the FS15 the only differences between the two shelves are the type and quantity of drives Front panel Disks After you unlock and remove the snap on bezel on the front panel the 15 disks are visible Disk numbers as reported by system commands range from 1 to 15 When facing the front panel Disk 1 is located in the leftmost slot in the enclosure and Disk 15 in the rightmost slot Figure 1 ES30 front...

Page 12: ...ious from a disk module light look at the back of the disk enclosure Disk enclosure power light 1 Blue Power to enclosure is on Disk active light 1 per disk module Green No LED when the slot is empty or has a filler module Also off when the disk is powered down by command for example the result of a temperature fault Fast blinking when the SATA SAS drive is powered up but not spinning this is a no...

Page 13: ...te When replacing a component note its orientation before removing it Insert the replacement in the same position Power supply A and controller A are located at the bottom of the chassis and power supply B and controller B are located at the top of the chassis Figure 3 Back panel Power modules and controllers 1 LEDs l Power supply B Power LED l Power fault Amber l Blower fault Amber 2 Expansion Ou...

Page 14: ...ng power on self test Host Link Active 1 per Controller Blue On when the host connection is active Expansion Link Active 1 per Controller Blue On when the expansion connection is active Power Supply Active 1 per power supply Green On when the power supply is operating Power Supply Fault 1 per power supply Amber On when the power supply is faulty or is not receiving AC line voltage Flashing when ei...

Page 15: ...condition and powers down the ES30 and FS15 unless you replace a module within two minutes Shelf Installation Overview Back panel Power cooling module and shelf controllers 15 ...

Page 16: ...Shelf Installation Overview 16 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 17: ...ements 20 l Racking and cabling 20 l Avamar integrated with Data Domain systems 21 l Rail kit 21 l Shelf cabling rules and guidelines 21 l Installing or adding ES30 and FS15 shelves 28 l Requirements for combining ES20s and ES30s 33 l Connecting power 73 l Types of cabinets and power connections 74 Installing the Shelves 17 ...

Page 18: ... in 2M 3M and 5M lengths The available ES30 cables with mini SAS connectors at both ends are 1M 2M 3M and 5M in length Note l The mini SAS connectors are keyed and labeled with an identifying symbol Host port is identifier with symbol and Expander Expansion port with symbol l The end that is marked with the circle symbol connects to the ES30 controller port marked with a circle l The connector end...

Page 19: ...ir latch assembly ES20 cables Note ES20 shelves are only supported on DD6300 DD6800 and DD9300 and DD9500 and DD9800 systems on a temporary basis when migrating storage from the ES20 shelves to ES30 shelves The following cables are available for the ES20 connections See the Data Domain ES20 Hardware Guide for more information l Data Domain controller to ES20 shelves 1M 2M and 5M l ES20 to ES20 she...

Page 20: ... concerns For more information see Connecting power on page 73 Racking and cabling The shelves are 3U and the Data Domain controller is either 2U or 4U For more information see your Data Domain system hardware overview Data Domain has adopted recommended racking guidelines The guidelines for some systems differ slightly from their specific Data Domain Extended Retention System options see the figu...

Page 21: ... of space below the node are left free for Avamar expansion The ES30 shelves occupying those positions must be moved thus the cabling may be very different than a standard configuration Note Avamar is not integrated with the DD6300 DD6800 and DD9300 and DD9500 and DD9800 systems Rail kit One of each of these items is included with each ES30 shelf Table 9 ES30 rail kit Rail kit Rack depth Slide Rai...

Page 22: ...r and are only supported on DD2500 DD4200 DD4500 DD6300 DD6800 DD7200 DD9300 DD9500 and DD9800 systems l DD OS 5 6 does not support the ES20 shelves on the DD9500 systems However in DD OS 5 7 and later ES20 shelves can be attached to a DD6300 DD6800 and DD9300 or DD9500 or DD9800 system only for the period of time necessary to complete the shelf migration process l DD OS 5 7 and later support 4TB ...

Page 23: ...D990 128 3x4 15 30 455 16 32 56 6 288 384 DD990 256 3x4 15 30 455 16 32 56 6 576 768 DD990 ER 4 256 4x4 15 30 455 16 32 7 8 1152 1536 DD990 w DD Cloud Tier 13 256 4x4 15 30 455 16 32 56 6 576 max additional 144 SAS dedicated to DD Cloud Tier 768 max additional 180 SAS dedicated to DD Cloud Tier DD2500 3 32 DD2500 3 64 1x4 SAS 30 45 No Support 4 1 108 135 DD42007 128 2x4 SAS 30 45 SATA 15 30 455 16...

Page 24: ...6 1x4 Optional SAS 30 45 60 N A11 5 1 144 180 DD6800 or DD6800w HA13 192 2x4 SAS 30 45 60 SATA 15 30 455 N A11 7 14 4 144 180 DD6800 w Expanded Capacity 12 13 192 2x4 SAS 30 45 60 SATA 15 30 455 N A11 7 14 4 288 360 DD6800 w Expanded Capacity w HA 12 13 192 2x4 SAS 30 45 60 N A11 7 14 4 288 360 DD6800 w ER 13 192 2x4 SAS 30 45 60 SATA 15 30 455 N A11 7 14 4 576 720 DD6800 w DD Cloud Tier 13 192 2x...

Page 25: ... SAS dedicated to DD Cloud Tier DD9300 13 192 2x4 SAS 30 45 60 SATA 15 30 455 N A11 7 14 4 384 480 DD9300 w Expanded Capacity12 13 384 2x4 SAS 30 45 60 SATA 15 30 455 N A11 7 14 4 720 900 DD9300 w Expanded Capacity or w HA 12 13 384 2x4 SAS 30 45 60 N A11 7 14 4 720 900 DD9300 w ER 13 384 2x4 SAS 30 45 60 SATA 15 30 455 N A11 7 14 4 1440 1800 DD9300 Expanded Capacity w DD Cloud Tier13 384 2x4 SAS ...

Page 26: ...64 1080 DD9500 w DD Cloud Tier 13 512 4x4 SAS 30 45 60 SATA 15 30 45 N A11 7 8 864 max additional 240 SAS dedicated to DD Cloud Tier 1080 max additional 300 SAS dedicated to DD Cloud Tier DD9500 w HA and DD Cloud Tier 13 512 4x4 SAS 30 45 60 N A11 7 8 864 max additional 240 SAS dedicated to DD Cloud Tier 1080 max additional 300 SAS dedicated to DD Cloud Tier DD9800 13 256 3x4 SAS 30 45 60 SATA 15 ...

Page 27: ...or later 6 5 shelves maximum with ES30 4 is the recommended maximum 4 shelves maximum with ES20 3 is the recommended maximum 7 The maximum shelf count for any specific drive shelf size might be less than the product of max shelves x max shelves per set 8 The raw capacity of an ES30 is 125 of the available capacity The raw capacity of an ES20 is 133 of the available capacity The calculation for max...

Page 28: ...elf for rack mounting l The documentation refers to two SAS HBAs If only one HBA is allowed in a system then use another port as defined later for that specific system l On an HA system add cables from the second node to open ports at the end of the sets The ports on the second node must connect to the same sets as the corresponding ports on the first node Ports on the Data Domain system s SAS HBA...

Page 29: ...e another port as defined for that specific system Cable a set that contains multiple shelves Procedure 1 Connect one SAS HBA port for example HBA 3 Port A on the Data Domain system to the top shelf controller s host port using a DD System to Shelf cable 2 Using another HBA card for example HBA 2 Port B connect a SAS port to the bottom shelf controller s host port using a DD System to Shelf cable ...

Page 30: ...Figure 5 Shelf cabling connections Installing the Shelves 30 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 31: ...given in the following tables Table 11 SAS HBA Card 3 recommended port connections DD860 DD890 systems Port D Port C Port B Port A Bottom of set 4 Top of set 3 Bottom of set 2 Top of set 1 Table 12 SAS HBA Card 2 recommended port connections DD860 DD890 systems Port D Port C Port B Port A Bottom of set 3 Top of set 4 Bottom of set 1 Top of set 2 4 Connect the shelves within a set by cabling expans...

Page 32: ...ller A to Shelf Controller A and Shelf Controller B to Shelf Controller B to create independent duplicate the paths Figure 7 Shelf set connection overview Installing the Shelves 32 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 33: ...XPANSION diamond connections Note l A shelf set must consist of either all ES20s or all ES30 shelves These two models cannot be mixed in the same shelf set l DD660 and DD690 support only two sets so if both ES20s and ES30s are used there is one set of each l The figures contain suggested cabling for Data Domain systems integrated with Avamar DD880 cabling Note DD OS 5 7 and later releases do not s...

Page 34: ... 7 9 ES20s 1 3 ES30s HBA Ports 3a 2b HBA Ports 2a 3b HBA Ports 3c 2d HBA Ports 2c 3d ES20 ES20 ES20 ES30 ES20 ES20 ES20 ES30 ES20 ES20 ES20 ES30 Table 15 Configuration C 1 to 3 ES20 and 7 to 9 ES30 shelves 1 3 ES20s 7 9 ES30s HBA Ports 3a 2b HBA Ports 2a 3b HBA Ports 3c 2d HBA Ports 2c 3d ES20 ES30 ES30 ES30 ES20 ES30 ES30 ES30 ES20 ES30 ES30 ES30 When there are seven shelves of one type to minimi...

Page 35: ...bine ES20 and ES30 shelves in the same set DD990 cabling There are a few rules that must be followed when adding both ES20 and ES30 shelves to a DD990 system l You can have a minimum of four shelves for a DD900 system with or without the Expended Retention software l You cannot exceed the maximum amount of raw capacity listed in Table 16 on page 40 below For this calculation ES20s can be counted a...

Page 36: ...0s Ensure sufficient redundant power in the rack l There are no specific placement or cabling requirements for the metadata shelves for DD Cloud Tier configurations These shelves can be installed and cabled the same way as standard ES30 shelves Note In expansion beyond 24 shelves when using the cable kits it may be necessary to swap cables Figure 9 Recommended DD990 cabling Installing the Shelves ...

Page 37: ...Figure 10 Recommended cabling for DD990 integrated with Avamar Installing the Shelves DD990 cabling 37 ...

Page 38: ...Figure 11 Recommended cabling for an extended retention or DD Cloud Tier system for DD990 Installing the Shelves 38 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 39: ...Figure 12 Recommended cabling for DD990 with extended retention and integrated with Avamar Installing the Shelves DD990 cabling 39 ...

Page 40: ...S20 V1 2 ES30 V4 2 ES20 V1 2 ES30 V5 1 ES20 V1 1 ES30 V5 1 ES20 V1 1 ES30 V4 1 ES20 V1 1 1 ES20 2 ES20 3 ES20 Note Those entries in the table marked with an asterisk are to be added last Table 17 DD990 cabling mixed ES20 and ES30 ES20 4 6 Rack 2 Rack 1 Rack 2 Rack 1 Rack 2 Rack 1 ES30 V4 5 ES30 V4 3 ES30 V4 5 ES30 V4 3 ES30 V4 4 ES30 V4 2 ES30 V4 4 ES30 V4 2 ES30 V4 4 ES30 V4 2 ES30 V4 3 ES30 V4 1...

Page 41: ...2 2 ES30 V6 1 ES20 V2 3 ES30 V5 1 ES20 V2 2 ES30 V5 1 ES20 V2 1 ES30 V5 5 ES20 V2 2 Empty DD990 Empty DD990 Empty DD990 ES30 V4 4 ES20 V2 1 ES30 V4 4 ES20 V1 4 ES30 V5 4 ES20 V2 1 ES30 V4 3 ES20 V1 3 ES30 V4 3 ES20 V1 3 ES30 V5 3 ES20 V1 3 ES30 V4 2 ES20 V1 2 ES30 V4 2 ES20 V1 2 ES30 V5 2 ES20 V1 2 ES30 V4 1 ES20 V1 1 ES30 V4 1 ES20 V1 1 ES30 V5 1 ES20 V1 1 7 ES20 8 ES20 9 ES20 Note Those entries ...

Page 42: ... this system are the same as the DD990 except the maximum number of ES30s for the Extended Retention system in a set is increased to 7 There is no change to the ES20 maximums The maximum number of shelves will be less than 56 because of the rules regarding the maximum number of ES20s in a set It is recommended that Professional Services be contacted for these large mixed shelf systems Data Domain ...

Page 43: ...Figure 13 Recommended DD2500 cabling Installing the Shelves DD2500 cabling 43 ...

Page 44: ...hese rules it is not a legitimate configuration Prerequisites l Follow the minimum and maximum shelf capacity configuration provided in the table l You cannot have ES20 and ES30 shelves in the same set l You cannot have ES30 SATA and ES30 SAS shelves in the same set l You cannot exceed the maximum amount of raw capacity displayed in the product s cabling table Installing the Shelves 44 Data Domain...

Page 45: ...sets of ES30 SATA shelves Finally there may be entries for the number of desired ES30 SAS shelves and the number of sets to be used If the combinations of shelves exceed the supported usable storage there may not be an entry The entries are based on the smallest usable storage per shelf type 12TB for ES20 12 TB for ES30 SATA and 24TB for ES30 SAS Always check that the sum of the usable storage of ...

Page 46: ... 1 1 4 1 1 5 1 5 7 2 1 4 1 0 0 1 4 1 1 4 1 0 0 5 7 2 0 0 13 16 4 0 0 0 0 9 12 3 1 3 1 0 0 5 8 2 1 4 1 0 0 5 8 2 5 2 0 0 1 4 1 1 4 1 0 0 1 4 1 5 7 2 0 0 0 0 1 4 1 0 0 0 0 5 8 2 Table 22 DD4500 cabling information DD4500 ES20 ES20 chains ES30 SATA ES30 SATA chains ES30 SAS ES30 SAS chains 13 16 4 0 0 0 0 9 12 3 1 5 1 0 0 9 12 3 0 0 1 5 1 5 8 2 1 5 1 1 5 1 5 8 2 6 8 2 0 0 5 8 2 0 0 1 5 1 Installing t...

Page 47: ...9 2 0 0 1 5 1 1 4 1 0 0 1 5 1 5 8 2 0 0 1 5 1 9 11 3 0 0 0 0 1 4 1 0 0 0 0 5 8 2 0 0 0 0 9 12 3 Table 23 DD7200 cabling information DD7200 ES20 ES20 chains ES30 SATA ES30 SATA chains ES30 SAS ES30 SAS chains 13 16 4 0 0 0 0 9 12 3 1 5 1 0 0 9 12 3 0 0 1 5 1 5 8 2 1 5 1 1 5 1 5 8 2 6 8 2 0 0 5 8 2 0 0 1 5 1 5 8 2 0 0 6 10 2 1 4 1 11 15 3 0 0 1 4 1 6 10 2 1 5 1 1 4 1 1 5 1 1 5 1 1 4 1 1 5 1 6 10 2 I...

Page 48: ... 2 6 10 2 0 0 1 5 1 1 5 1 0 0 1 5 1 6 10 2 0 0 1 5 1 11 15 3 0 0 0 0 1 4 1 0 0 0 0 5 8 2 0 0 0 0 9 12 3 0 0 0 0 13 16 18 4 The following figures show cabling for base systems systems with the Extended Retention software option and systems integrated with an Avamar system Installing the Shelves 48 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 49: ...Figure 15 Recommended DD4200 cabling Installing the Shelves DD4200 DD4500 and DD7200 cabling 49 ...

Page 50: ...Figure 16 Recommended cabling for DD4200 integrated with Avamar Installing the Shelves 50 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 51: ...Figure 17 Recommended cabling for DD4200 system with extended retention software or DD Cloud Tier Installing the Shelves DD4200 DD4500 and DD7200 cabling 51 ...

Page 52: ...Figure 18 Recommended cabling for DD4200 with extended retention and integrated with Avamar Installing the Shelves 52 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 53: ...Figure 19 Recommended DD4500 cabling Installing the Shelves DD4200 DD4500 and DD7200 cabling 53 ...

Page 54: ...Figure 20 Recommended cabling for DD4500 integrated with Avamar Installing the Shelves 54 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 55: ...Figure 21 Recommended cabling for DD4500 with extended retention software or DD Cloud Tier Installing the Shelves DD4200 DD4500 and DD7200 cabling 55 ...

Page 56: ...Figure 22 Recommended cabling for DD4500 with extended retention and integrated with Avamar Installing the Shelves 56 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 57: ...Figure 23 Recommended DD7200 cabling Installing the Shelves DD4200 DD4500 and DD7200 cabling 57 ...

Page 58: ...Figure 24 Recommended cabling for DD7200 integrated with Avamar Installing the Shelves 58 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 59: ...Figure 25 Recommended cabling for DD7200 with extended retention software or DD Cloud Tier Installing the Shelves DD4200 DD4500 and DD7200 cabling 59 ...

Page 60: ...Figure 26 Recommended cabling for DD7200 with extended retention and integrated with Avamar Installing the Shelves 60 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 61: ...be installed and cabled the same way as standard ES30 shelves Table 24 Minimum and maximum configurations System Appliance Minimum appliance shelf count Max appliance shelf count DD6300 48 TB usable 0 1 DD6300 w Expansion 144 TB usable 1 5 DD6800 144 TB usable 2 28 DD6800 w Expansion 288 TB usable 2 28 DD6800 w High Availability HA 288 TB usable 2 28 DD6800 w Extended Retention ER 576 TB usable 2 ...

Page 62: ...92 TB for DD Cloud Tier 7 28 The minimum appliance shelf count does not include shelves for DD Cloud Tier The cabling diagrams in this section show the maximum configurations for DD6300 DD6800 and DD9300 systems Not all systems will have all the disk shelves shown in the diagrams Installing the Shelves 62 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 63: ...Figure 27 Recommended cabling for DD6300 with maximum configuration Installing the Shelves DD6300 DD6800 and DD9300 cabling 63 ...

Page 64: ...re 28 Recommended cabling for DD6800and DD9300 single node DD Cloud Tier or ER systems with maximum configuration Installing the Shelves 64 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 65: ...Figure 29 Recommended cabling for DD9300 with HA and HA with DD Cloud Tier Installing the Shelves DD6300 DD6800 and DD9300 cabling 65 ...

Page 66: ...es for DD Cloud Tier configurations These shelves can be installed and cabled the same way as standard ES30 shelves Table 25 Minimum and maximum configurations System DD9500 DD9500 w FS15 DD9800 Appliance 864 TB usable 864 TB usable 1008 TB usable Minimum appliance shelf count 4 4 4 Maximum appliance shelf count 30 30 30 Extended Retention systems ER 1728 TB usable 2016 TB usable 2016 TB usable Ma...

Page 67: ...elves Note The racks are filled from bottom up The cabling diagrams in this section show the maximum configurations for the DD9500 and DD9800 systems Not all systems will have all the disk shelves shown in the diagrams Installing the Shelves DD9500 and DD9800 cabling 67 ...

Page 68: ...Figure 30 Cabling for base DD9500 DD9800 systems Installing the Shelves 68 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 69: ...Figure 31 Cabling for HA DD9500 DD9800 systems in one rack Installing the Shelves DD9500 and DD9800 cabling 69 ...

Page 70: ...Figure 32 Cabling for HA DD9500 DD9800 systems in two racks Installing the Shelves 70 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 71: ...Figure 33 Cabling for DD9500 DD9800 systems with DD Cloud Tier Single node or HA Installing the Shelves DD9500 and DD9800 cabling 71 ...

Page 72: ...Figure 34 Cabling for DD9500 DD9800 systems with ERSO Installing the Shelves 72 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 73: ...stem CAUTION Ensure that the PDU can handle the overall power load l The rack s electrical distribution and earth ground bonding must meet the requirements of UL 60950 1 and IEC 60950 1 and local electrical safety building codes l The PDUs must have a sufficient quantity of single phase power outlets with an earth ground conductor safety ground A safe electrical earth ground connection must be pro...

Page 74: ...nel of the ES30 shelf to a PDU with power 7 If multiple racks are used complete the cabling of all shelves in all racks before applying power Types of cabinets and power connections The ES30 chassis is installed in two types of racks 40U C existing racks and the 40U P newer racks The racks use one phase or 3 phase power connections This section describes the different types of racks and the power ...

Page 75: ...owing figures show single phase power connections for 40U P racks used for several Data Domain systems Figure 36 Recommended single phase power connections for the 40U P expansion rack Installing the Shelves Single phase power connections for 40U P current racks 75 ...

Page 76: ...Figure 37 Recommended single phase power connections for the DD860 and DD890 Installing the Shelves 76 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 77: ...Figure 38 Recommended single phase power connections for the DD990 Installing the Shelves Single phase power connections for 40U P current racks 77 ...

Page 78: ...Figure 39 Recommended single phase power connections for the DD2500 Installing the Shelves 78 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 79: ...Figure 40 Recommended single phase power connections for the DD4200 DD4500 and DD7200 Installing the Shelves Single phase power connections for 40U P current racks 79 ...

Page 80: ...Figure 41 Recommended single phase power connections for DD6300 DD6800 and DD9300 Installing the Shelves 80 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 81: ...Figure 42 Recommended single phase power connections for the DD9500 DD9800 Installing the Shelves Single phase power connections for 40U P current racks 81 ...

Page 82: ...Figure 43 Recommended single phase power connections for the DD9500 HA Installing the Shelves 82 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 83: ...ollowing figures show single phase power connections for 40U C racks used for several Data Domain systems Figure 44 Recommended single phase power connections for the Expansion Rack Installing the Shelves Single phase power connections for 40U C older racks 83 ...

Page 84: ...Figure 45 Recommended single phase power connections for a DD860 and DD890 Installing the Shelves 84 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 85: ...Figure 46 Recommended single phase power connections for the DD990 Installing the Shelves Single phase power connections for 40U C older racks 85 ...

Page 86: ...Figure 47 Recommended single phase power connections for the DD2500 Installing the Shelves 86 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 87: ...ns it is desirable to balance the current draw across all 3 phases The recommended 3 phase power cabling attempts to do that but an optimal configuration is dependent on the specific installation The following figures show recommended 3 phase power connections for several Data Domain systems Note The next few diagrams show recommended 3 phase delta power connections Installing the Shelves 3 Phase ...

Page 88: ...Figure 49 Recommended 3 phase delta power connections for the Expansion Rack Installing the Shelves 88 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 89: ...Figure 50 Recommended 3 phase delta power connections for DD860 and DD890 Installing the Shelves 3 Phase power connections for 40U P current racks 89 ...

Page 90: ...Figure 51 Recommended 3 phase delta power connections for DD860 with Extended Retention Installing the Shelves 90 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 91: ...Figure 52 Recommended 3 phase delta power connections for DD990 Installing the Shelves 3 Phase power connections for 40U P current racks 91 ...

Page 92: ...Figure 53 Recommended 3 phase delta power connections for DD4200 DD4500 and DD7200 Installing the Shelves 92 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 93: ...Figure 54 Recommended 3 phase delta power connections for DD2500 Installing the Shelves 3 Phase power connections for 40U P current racks 93 ...

Page 94: ...Figure 55 Recommended 3 phase delta power connections for DD6300 DD6800 and DD9300 Installing the Shelves 94 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 95: ...Figure 56 Recommended 3 phase delta power connections for DD9500 DD9800 Installing the Shelves 3 Phase power connections for 40U P current racks 95 ...

Page 96: ...Figure 57 Recommended 3 phase delta power connections for DD9500 DD9800 HA Installing the Shelves 96 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 97: ...xt few diagrams show recommended 3 phase wye power connections Figure 58 Recommended 3 phase wye power connections for the Expansion Rack Installing the Shelves 3 Phase power connections for 40U P current racks 97 ...

Page 98: ...Figure 59 Recommended 3 phase wye power connections for DD860 and DD890 Installing the Shelves 98 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 99: ...Figure 60 Recommended 3 phase wye power connections for DD860 with Extended Retention Installing the Shelves 3 Phase power connections for 40U P current racks 99 ...

Page 100: ...Figure 61 Recommended 3 phase wye power connections for DD990 Installing the Shelves 100 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 101: ...Figure 62 Recommended 3 phase wye power connections for DD2500 Installing the Shelves 3 Phase power connections for 40U P current racks 101 ...

Page 102: ...Figure 63 Recommended 3 phase wye power connections for DD4200 DD4500 and DD7200 Installing the Shelves 102 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 103: ...Figure 64 Recommended 3 phase wye power connections for DD6300 DD6800 and DD9300 Installing the Shelves 3 Phase power connections for 40U P current racks 103 ...

Page 104: ...Figure 65 Recommended 3 phase wye power connections for DD9500 DD9800 Installing the Shelves 104 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 105: ...Figure 66 Recommended 3 phase wye power connections for DD9500 DD9800 HA Installing the Shelves 3 Phase power connections for 40U P current racks 105 ...

Page 106: ...ss all 3 phases The recommended 3 phase power cabling attempts to do that but an optimal configuration is dependent on the specific installation The following figures show recommended 3 phase power connections for several Data Domain systems Figure 67 Recommended 3 phase power connections for the Expansion Rack Installing the Shelves 106 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware...

Page 107: ...Figure 68 Recommended 3 phase power connections for DD860 and DD890 Installing the Shelves 3 Phase power connections for 40U C older racks 107 ...

Page 108: ...Figure 69 Recommended 3 phase power connections for DD990 Installing the Shelves 108 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 109: ...Figure 70 Recommended 3 phase power connections for DD2500 Installing the Shelves 3 Phase power connections for 40U C older racks 109 ...

Page 110: ...Figure 71 Recommended 3 phase power connections for DD4200 DD4500 and DD7200 Installing the Shelves 110 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 111: ... ES30 shelves See the appropriate description for your DD system l DD640 DD670 DD860 and DD890 systems 112 l DD660 and DD690 systems 112 l DD880 systems 113 l DD990 systems 113 l DD2500 systems 114 l DD4200 DD4500 and DD7200 systems 114 l DD6300 DD6800 and DD9300 systems 115 l DD9500 and DD9800 systems 117 Data Domain Specific Installation 111 ...

Page 112: ...software formerly called the DD860 Archiver has three quad port SAS cards installed The other systems have two quad port SAS cards Figure 72 DD640 670 860 890 rear panel Figure 73 DD640 670 860 890 PCI slot numbering DD660 and DD690 systems Note DD OS 5 7 and later releases do not support the DD660 and DD690 systems SAS HBA ports The SAS cards are located in PCI slot 4 SAS 1 and PCI slot 3 SAS 2 P...

Page 113: ...ling rules and guidelines on page 21 for configuration information SAS HBA ports Figure 75 DD880 rear panel DD990 systems DD990 systems have three dual port SAS cards installed in slots 4 5 or 9 and Extended Retention Systems for the DD990 have four dual port SAS cards installed in slots 4 5 8 or 9 There are 11 HBA PCI cards that are numbered 1 11 from right to left On each card the topmost port i...

Page 114: ...e management module is located on the far left side when facing the back of the system in slot Management A The management module contains one external LAN connection for management access to the system processor SP module One micro DB 9 connector is included to provide the console A USB port is provided for use during service of the system to allow booting from a USB flash device All systems cont...

Page 115: ... I O modules for systems with Extended Retention or DD Cloud Tier DD6300 DD6800 and DD9300 systems DD6300 DD6800 and DD9300 Onboard IO is on the left of the rear side of the SP A DB 9 port is used as a serial console and a USB 2 0 compliant port is for performing DDOS upgrades There are two 1000BaseT network port the left port connects to a dedicated BMC service port and the right port is a genera...

Page 116: ...Slot 7 Note Slots 2 and 7 are used for SAS I O modules DD6300 systems use only slot 7 when the SAS module is needed Table 26 DD6300 DD6800 and DD9300 I O module slot assignments Slot Number DD6300 DD6800 DD9300 0 NVRAM NVRAM NVRAM 1 10GbE 10GbE 10GbE 2 Reserved SAS SAS 3 SAS SAS SAS 4 FC Ethernet or empty FC Ethernet or empty FC Ethernet or empty 5 FC Ethernet or empty FC Ethernet or empty FC Ethe...

Page 117: ...to right Figure 81 Rear of the DD9500 and DD9800 system 1 Power supply units 2 Management module 3 NVRAM and I O modules slots 0 11 I O module slot assignments The following figure shows the location of the NVRAM and I O modules Figure 82 Location of NVRAM and I O modules 1 NVRAM module slot 0 2 I O modules slots 1 to 11 See the I O module slot assignments table Note Slots 2 3 and 6 three I O slot...

Page 118: ...AS SAS 3 SAS SAS SAS SAS 4 FC Ethernet or empty FC Ethernet or empty FC Ethernet or empty FC Ethernet or empty 5 FC Ethernet or empty FC Ethernet or empty FC Ethernet or empty FC Ethernet or empty 6 SAS SAS SAS SAS 7 FC Ethernet or empty FC Ethernet or empty FC Ethernet or empty FC Ethernet or empty 8 FC Ethernet or empty FC Ethernet or empty FC Ethernet or empty FC Ethernet or empty 9 Not availab...

Page 119: ...ves in their racks follow the instructions in this chapter to complete the setup This chapter covers these major topics l Add shelf capacity licenses 120 l Power on sequence 121 l Verifying shelf installation 123 l Add enclosure disks to the volume 126 Post Installation Tasks 119 ...

Page 120: ...e license is required Procedure 1 To add shelf capacity licenses enter the license add command followed by one or more license keys separated with a space For example license add Capacity Active license 2 Issue the storage add tier command once for each enclosure that is to be added to a tier For example for a standard Data Domain system storage add tier active enclosure enclosure id For a Data Do...

Page 121: ... functioning properly l The shelf s power LED is green l Each Controller s power LED is green 5 Verify that there are no amber fault LEDs l If the Power Supply Fault LED is steady amber the power supply is faulty or is not receiving AC line voltage If it is flashing either a multiple blower or ambient over temperature condition has shut off DC power to the system l If the Controller Fault LED is a...

Page 122: ...on Note The power supplies of controller A is located at the top of the shelf and the power supply of controller B is located at the bottom of the shelf 6 If there are no amber LEDs wait a few minutes after the final shelf was powered on before restarting the Data Domain system Figure 84 Back panel Power modules controller B above controller A 1 LEDs Power Supply B Power LED Power fault Amber Blow...

Page 123: ...the SAS HBA Verifying shelf installation The Data Domain system recognizes all data storage system and attached shelves as part of a single file system volume WARNING l Do not remove or disconnect a shelf that has been added earlier If a shelf is disconnected the file system volume is immediately disabled and all data in the volume is lost l To re enable a shelf reconnect the shelf or transfer the...

Page 124: ...F 4 U U U U U U U U U U U U U U U 5 A K v K K K K K K v K K K K R Legend State Count In Use Disks 4 s Spare Disks 1 R Spare reconstructing Disks 1 v Available Disks 2 K Known Disks 11 U Unknown Disks 43 F Failed Disks 1 A Absent Disks 1 Total 64 disks Note Run the storage add command to add disks in the U state to the Data Domain system 3 Verify that the Data Domain system recognizes each attached...

Page 125: ... 3 A E 2 A H 2 A E 3d Encl WWN Serial 2 N A APM00134300550 3 N A APM00134300549 4 N A APM00134300556 5 N A APM00134300555 Error Message No error detected ES20 rear view CONTROLLER B CONTROLLER A OP PANEL E H H E ES30 rear view CONTROLLER B E H CONTROLLER A H E 5 Run the enclosure test topology command to validate SAS cable connections enclosure test topology 2b 2 B H duration 1 HBA Information Por...

Page 126: ... Duration 62 Date and time Tue Sep 20 14 17 26 2016 Timestamp 1474406246 Port enc ctrl port 2b 2 B H 2 B E Error message No error detected Add enclosure disks to the volume Procedure 1 When prompted enter your sysadmin password 2 Enter the storage show all command to display the RAID groups for each shelf storage show all Active tier details Disk Disks Count Disk Additional Group Size Information ...

Page 127: ... 21 8 TiB CAPACITY ACTIVE DS60 152 7 TiB 32 7 TiB 120 0 TiB One disk in a shelf is a spare disk The rest should report that they are available 3 Enter the filesys expand command to allow the file system to use these enclosure disks filesys expand 4 Enter the filesys enable command to enable the file system filesys enable 5 Enter the disk show state command to verify the disks disk show state Enclo...

Page 128: ... Legend State Count In Use Disks 3 v Available Disks 60 U Unknown Disks 75 Total 138 disks Post Installation Tasks 128 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide ...

Page 129: ...APPENDIX A Hardware Specifications This appendix contains the following topics l ES30 and FS15 hardware specifications 130 Hardware Specifications 129 ...

Page 130: ... x 105 J hr 800 Btu hr max Dimensions rack mounted with bezel l Width 17 62 45 cm Depth 14 35 56cm l Height 5 25 13 34cm 3 RU Maximum Weight 68 lbs 30 8 kg Operating Temperature l Ambient temperature 10o C to 35o C 50o F to 95o F l Temperature gradient 10o C hr 180o F hr l Relative humidity extremes 20 to 80 noncondensing Recommended Operating Relative Humidity 40 to 55 noncondensing Non Operating...

Reviews: